Chromalox PD444-2 User Manual

Chromalox, Installation instructions, Type gxf/gtf/gtfl series grounded teflon

Advertising
background image

Chromalox

®

DIVISION

4

SECTION

GTF

SALES

REFERENCE

DATE

SERVICE REFERENCE

Installation Instructions

PD444-2

161-562652-001

DECEMBER, 2004

(Supersedes PD444-1)

© 2010 Chromalox, Inc.

GENERAL

FIRE/EXPLOSION HAZARD: This heater is not
intended for use in hazardous atmospheres where
flammable vapors, gases, liquids, or other com-
bustible atmospheres are present as defined in
the National Electrical Code. Failure to comply can
result in explosion or fire.

Chromalox type GTF series of Teflon

®

over-the-side immer-

sion heaters are especially suited for most plating tank and other
corrosive solutions. It is inert to acid baths, anodizing and picking
operations up to 212˚F solution temperatures.

Sheath corrosion can result in a ground fault
which, depending upon the solution being heated,
can cause an explosion or fire.

IMPORTANT: It is the responsibility of the pur-
chaser of the heater to make the ultimate choice
of sheath material based upon his knowledge of
the chemical composition of the corrosive solu-
tion, character of the materials entering the solu-
tion, and controls which he maintains on the
process.
Chromalox cannot warrant any electric immersion
heater against failure by sheath corrosion if such failure is the
result of operating conditions beyond our control.

1. Heater Construction Characteristics

A. High quality resistance wire held in place by compacted mag-

nesium oxide in stainless steel sheath and Teflon

®

covered.

B. Low watt density.
C. Grounded construction.
D. Over-temperature protection.
E. Epoxy filled, vapor tight, plastic terminal enclosure prevents

entry of contaminants.

F. Flexible conduit 3’ long with 6” leadwire extension is stan-

dard.

The system designer is responsible for the safety
of this equipment and should install adequate
back-up controls and safety devices with their
electric heating equipment. Where the conse-
quences of failure could result in personal injury
or property damage, back-up controls are essen-
tial.

Chromalox

®

Type GXF/GTF/GTFL Series

Grounded Teflon

®

Immersion Heaters

GTFL3

GTF6

* Teflon

®

is a registered trademark of DuPont Co.

GTF

GXF/GXFL

Advertising