Auto speaker setup for distance/level, Level calibration – Cambridge Audio AZUR 551R User Manual

Page 16

Advertising
background image

16

The 551R allows level calibration to match the acoustic level between

different types/sizes or even manufacturers of speaker that may be being

used for each channel. This is achieved by adjusting the relative level of each

speaker. This can be done manually through the ‘Level Calibration’ menu in

the OSD or automatically, see the following Auto setup section of this manual.
The basic process for manual adjustment is to listen to or measure with a

Sound Pressure Level (SPL) meter (more accurate and recommended but not

essential) the level of sound produced by each speaker and set relative levels

for each speaker so that they all sound the same loudness at the normal

listening position. The 551R incorporates a Test Signal Generator (broad-

band white noise) to facilitate this.
Press the OSD button on the remote control then select the ‘Level

Calibration’ menu. Now turn on the test signal by highlighting this item and

pressing the Left or Right arrows:

You can now move up and down the channels using Volume Up/Down on the

remote. Each time a new channel is selected the test signal will be heard to

move to that channel. Compare the loudness of all channels as heard at the

listening position.
A “rushing” or “hissy” sound should be heard.

Now adjust the channels so they all sound the same (in terms of loudness

only, channels of different frequency responses can sound different in terms

of the “tone” of the sound i.e. more or less hissy).
Pick the channel that sounds most different and select it to listen to the test

signal. Now adjust the relative level in dB (using Arrow left/right on the

remote) and continue comparing it to other channels until it is of equal

loudness. The level can be adjusted up to + or - 10dB in 1dB steps. Repeat

the process with the next most different channel. Once all channels sound

the same in terms of loudness, press the OSD button again to save the

settings and exit the menu.

Auto speaker setup for Distance/Level

The 551R includes our simple automatic speaker setup system called

'CAMCAS' (Cambridge Audio Mic Controlled Auto Setup). The system performs

two sets of tests firstly checking which speakers are connected and whether

they are wired correctly and in phase then second automatically measuring

and adjusting the speaker delay timings (i.e. distance setting ) and levels.
Before activating this feature the 'Decode Mode' (i.e. type of speaker

package e.g. 5.1, 7.1) of the 551R and Large/Small/None status of each

speaker must be set correctly as per section 1. This is important as the unit

will only look for and check the speakers you have told it you have.

Level calibration

Level Calibration Menu

Test Signal

:

Front L

:

Front R

:

Surround L

:

Surround R

:

Centre

:

Subwoofer

:

Surr. LB

:

Surr. RB

:

Return : [OSD]

On

0 dB
0 dB
0 dB
0 dB
0 dB
0 dB
0 dB
0 dB

To perform Auto Distance/Level setup first connect the supplied microphone

to the front Left front panel audio input on the front panel and place it at your

normal listening position in the room.
Press the OSD button on the remote control to access the OSD and then

select the Speaker Setup Menu. Now select the option 'Auto Setup'. This will

access the 'Auto Setup Menu' as below.

Follow the on-screen instructions and press 'Enter' on the remote control

when ready to start the Auto Setup function.

Once activated the OSD will display the message below and the word

'AUTOSETUP' will also be displayed on the front panel of the 551R to confirm.

A series of test signals will now be output from all of the connected speaker

terminals of the 551R (including the Subwoofer output).
Once finished the unit will display a screen similar to the one below reporting

which speakers were found and any that appear out of phase.

If any speakers appear unconnected or out of phase carefully check the

connections on the speaker and the back of the unit. Also check any bi-wiring

links that might be present on the speaker. For any out of phase speakers

check that the relevant + terminal of the 551R goes to the + terminal of that

speaker and similarly the – terminal of the 551R goes to the – terminal of the

speaker for that channel.

Auto Setup Menu

Continue : [ENTER]

Plug the microphone into the left channel of Video
3 on the front panel and place the microphone at
normal listening position and height

Auto Setup Menu

The unit is now checking which speakers are
connected and their phase

Please wait........

Auto Setup Menu

Continue : [ENTER]

The speakers that have been found are:
L C R SL SR LB RB SW
All speakers are in phase

Speaker Setup Menu

Auto Setup
Speaker Configuration
Speaker Distance
Level Calibration
Speaker Crossover

Return : [OSD]

Advertising