Burner and Nozzle Specifications

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

Thermal Power

kW (p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Thermal Power

kW (p.c.s.*)

Nozzle

1/100

Flow*

l/h

(mm)

Nominal

Reduced

(mm)

(mm)

***

**

Nominal

Reduced

(mm)

Fast
(Large)(R)

100

94

2,60

0,7

41

80

189

186

2,60

0,7

118

248

Semi Fast
(Medium)(S)

75

69

1,90

0,4

30

70

138

136

1,90

0,4

104

181

Auxiliary
(Small)(A)

51

46

1,00

0,4

30

52

73

71

1,00

0,4

76

95

Main Oven

-

-

2,60

0,6

36

71

189

186

2,60

0,6

123

248

Grill

-

-

3,60

2,4

-

94

240

236

3,60

1,3

134

343

Top Oven

-

-

2,00

0,6

34

66

145

143

2,00

0,6

104

190

Supply
Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20
17
25

*

At 15°C and 1013 mbar- dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

Natural

P.C.S. = 37,78 MJ/m