Restart after a power failure

Specific behavior of the single cycle

Password list

In case a power failure occurs while a program is

running, the following information will be stored

in memory : number of the program under way,

the residual time, the phase under way and any
other data required to restore the operating

conditions in force right before the power failure.

When the power supply is restored, the display

indicates the program interrupted, and the user

can press ENTER to start it or STOP to stop it for
good.

The execution of a single cycle is rather simple

compared to that of a complete program. In case
of single cycle, a group of settings is carried out

using standard values (not set by the user),

namely:

The basket rotation time is set for 20 seconds
Pause time during basket rotation is also 20

seconds

The cooling down phase lasts 5 minutes or

until a temperature of 35°C is reached

At the end of the program the buzzer goes off
for 2 seconds

The anti-crease cycle is not carried out at the

end of the program

Following is a list of available passwords and

their purpose:

CODE

FUNCTION

748

Access to Machine Configuration

916

Access to Operating Ranges

955

Access to Cycle Programming

750

Reset control to defaults

383

Access to test procedure

743

Display working hour counter

347

Reset working hour counter

666

Set to on signal for reset gas control unit

667

Set to off signal for reset gas control unit