Bradford White D-80T-725-3X User Manual

Technical support

Advertising
background image

ICON - Power Vent and Power Direct Vent

Water Heaters

ERROR CODE

DEFINITION

SERVICE ACTION

POSSIBLE PARTS NEEDED

No LED

No power to the unit or switch is off

Turn power on

None

Verify 120 volts present at outlet

One short flash every 4 seconds

Standby mode/unit up to temp

None

None

Bright/dim alternating LED

Thermostat calling for heat

None

None

Short flash once every second

Weak pilot signal on last call for heat

Inspect and clean pilot assembly

1) Pilot assembly

Check continuity on flame sensor

2) Gas valve

Two flashes three second pause

Pressure switch not working - closed position

Inspect pressure switch tubing and ports

1) Pressure switch

Bypass pressure switch

2) Temp switch

& temp switch for testing
Measure vacuum on pressure switch

Three Flashes three second pause

Pressure switch or temp switch stuck open

Check vent for blockage

1)Pressure switch

Verify blower spinning up to speed

2) Temp switch

Measure vacuum on pressure switch

3) Blower assembly

Inspect pressure switch tubing and ports

4) Gas valve

Bypass pressure switch
& temp switch for testing

Four flashes three second pause

High tank temperature

Check temp probe ohms -

1) Thermowell

compare with sensor temp chart

2) Gas valve

Five flashes three second pause

False pilot flame sensed/pilot valve stuck open

Check for flame sensor short to ground

1) Pilot assembly

Gas valve stuck open - replace valve

2) Gas valve

Six flashes -

Pilot failed to light

Inspect and clean pilot,

1) Pilot assembly

one flash, three second pause

Check connection at gas valve
Verify gas flow

2) Gas valve

Six flashes -

Pressure switch or temp switch

Check vent for blockage

1) Pressure switch

two flashes, three second pause

opened during operation

Measure vacuum on pressure switch

2) Temp switch

Verify blower spinning up to speed

3) Blower assembly

Bypass pressure switch
& temp switch for testing

Six flashes -

Pilot flame extinguished

Inspect and clean pilot

1) Pilot assembly

three flashes, three second pause

Check connection at gas valve

2) Gas valve

Six flashes -

False pilot flame sensed/pilot valve stuck open

Check for flame sensor short to ground

1) Pilot assembly

four flashes, three second pause

Verify gas valve stuck open - replace valve

2) Gas valve

Seven flashes

Flammable vapor sensor fault

Verify resistance is between 3.0 - 4.8 KOhms 1) Flammable vapor sensor
Verify no flammable vapors present

2) Harness

Check sensor harness

Eight flashes -

Flammable vapor sensor out of spec, possible short

Verify resistance is between 3.0 - 4.8 KOhms 1) Flammable vapor sensor

one flash, three second pause

Verify no flammable vapors present

2) Harness

Check sensor harness

3) Gas valve

Eight flashes -

Thermowell sensor damaged or unplugged

Check temp probe ohms -

1) Thermowell

two flashes, three second pause

compare with sensor temp chart

2) Gas valve

Eight flashes -

Gas valve electronics fault

Reset gas valve, If problem persists

1) Gas valve

three flashes, three second pause

replace gas valve

Eight flashes -

Gas valve fault detected

Reset gas valve, If problem persists

1) Gas valve

four flashes, three second pause

replace gas valve

NOTE:

Check all wire connections
Check gas inlet and manifold gas pressure
Check for grounding connections

Technical Support

800-334-3393