Control timings, Specifications – Bradford White TW4-75S-76B-3X User Manual

Page 9

Advertising
background image

Control Timings

Ignition State

Timing

Pre-purge

2 Seconds

Trial for Ignition

90 Seconds

Flame Stabilization Period

3 Seconds

Inter-purge

15 Seconds

Flame Failure Response Time

1.5 Seconds (2 second. Maximum; 1 second minimum.)

Post-purge

15 Seconds

PS Fault Delay (failed open/close)

Retry after 2 Minutes

Soft Lockout

Retry after 5 Minutes

TCO Limit Lockout

Indefinite (cycle power to restart)

Simulated Resistive Load Lockout

Indefinite (cycle power to restart)

Hardware Error Lockout

Indefinite (self clears if fault clears for at least 15 seconds)

Verify Resistive Delay

Retry after 2 Minutes (repeats 5 times)

Specifications

Page 9

A

C

B

Blower

Motor

Blower

Temperature

Switch

Pressure

Switch

Pilot

Blower

Housing

Wiring Diagram

Simulated

Resistive

Device

Thermal

Well