background image

ICON - Ultra Low NOx Water Heaters

ERROR CODE

DEFINITION

SERVICE ACTION

POSSIBLE PARTS NEEDED

No LED

No pilot light / Heater not in operation

Follow lighting instructions

1) None

on the water heater

One flash & three second pause

Knob in pilot position or thermostat satisfied

None

1) None

LED on continuously

Control knob turned to the off position

Wait for LED to go off before relighting

1) None

Two flashes & three second pause

Weak pilot signal detected

Verify pilot is lit

1) Pilot assembly

Check thermopile voltage output

2) Gas valve

Check wire connections at gas valve

Three flashes & three second pause

Control has not seen temp rise

Check temp probe ohms

1) Gas valve

in proper amount of time

Check gas pressure
Verify water is not flowing

Four flashes

High tank temperature

Check temp probe ohms

1) Thermowell

& three second pause

Check gas valve

2) Gas valve

Five flashes & three second pause

Thermostat sensor fault

Check temp probe ohms

1)Thermowell

Check gas valve cover

2) Gas valve

Six flashes & three second pause

Chamber door temp sensor out of specification

Check door sensor ohms

1) Chamber door sensor

Clean screenlok
Clean burner

Seven flashes

Gas valve fault

Reset gas valve; if problem persists

1) Gas valve

& three second pause

replace gas valve

Eight flashes

Pilot remains lit while the control knob

Check gas pressure

1) Gas valve

& three second pause

is in off position

Replace gas valve

Ten flashes & three second pause

Insufficient combustion air detected

Check gas pressure

1) Chamber door sensor

Clean screenlok
Check venting
Clean burner

NOTE:

Check all wire connections
Check gas inlet and manifold gas pressure
Check for grounding connections

Technical Support