Blower removal – Bradford White U-TW4-75S-76R-3N User Manual

Page 43

Advertising
background image

Page 43

Remove the Blower to Gain Access to the Flue Baffle

Step 1.

Move the gas control p o w e r

switch to the “OFF” position.

Step 2.

U np l ug t h e wa te r h e a t e r

from the wall outlet.

Step 3.

Disconnect the vent system from

the exhaust adapter on top of blower.

Step 4.

Unplug the cord sets from the

blower.

Step 5.

Remove the three blower mounting screws (1/4” nut driver).

Step 6.

Remove the blower with gasket from the

top of the water heater.

Step 7.

Remove the flue baffle from the

Blower Removal

Gas control power

switch

TTW (water heater)

power cord

Exhaust adapter

Blower mounting

screws

Blower cord sets

Flue baffle

43