3

1)

2)

3)

Remove lower panel cover.

Connect one wire from each valve to the desired

corresponding number on the terminal.

Connect the remaining valve wire from all the valves

to the “Com” or common terminal. It is suggested

to use a different color wire for the common wire

to help keep organized. “Common” wires may be

bundled or wired together with all other common

wires from all the valves to the “Com” terminal of

the controller.

CONNECTING VALVE WIRES TO CONTROLLER

Locate controller within 5 ft. of a standard electrical

outlet that provides continuous, uninterrupted power.

Do not install controller within 15 ft. of a pump, pump

start relay or any high voltage junction boxes or elec-

tric motors.

Choose desired location and install one screw for top

keyhole into wall. Remove bottom panel and insert

two additional screws in each of the bottom corners in

the holes provided. Use screw anchors if attaching to

drywall or masonry.

1)

2)

MOUNTING THE HDC CONTROLLER