ITW Linx SurgeGate AC User Manual

Page 2

Advertising
background image

The SurgeGate series has been designed with flexibility and expansion in mind.

Additional signal line protection can easily be added with SurgeGate protection

modules.

All SurgeGate 4 units are equipped with 4 AC outlets (SurgeGate 8 KSU has 8

AC outlets) controlled by a master switch. These models also feature SurgeGate

Plus™ circuitry for over and under-voltage protection. This circuitry protects

against brownouts (under-voltages) and/or prolonged over-voltages by

automatically disconnecting the power to your equipment, then reconnecting it

when the power has returned to a safe level. This special circuitry acts as a

gate to prevent unsafe voltages from damaging your equipment:

voltage OK = power connected;

voltage unsafe = power disconnected.

In addition, all units have four diagnostic lights for maximum safety. They are

designed as follows:

1. Ground OK— (green) normally ON —

indicates that the wall outlet is properly grounded.

2. Line Fault— (red) normally OFF —

when lit, indicates that the wall outlet is improperly wired.

3. Power ON and Protection OK— (green) normally ON —

indicates that the surge protector is functioning properly, power is on, and

it is protecting all connected equipment.

4. Unsafe Voltage— (red) normally OFF —

when lit, indicates that incoming voltages are unsafe and the surge protector

has disconnected the power to protect your equipment.

If you have any questions about which product is best for your applications,

please check our web site www.itwlinx.com or contact ITW Linx Customer

Service Department at

1-800-336-LINX(5469).

1. Turn

OFF the power to all equipment that will be plugged into the unit.

2. Make sure the

on/off switch is in the off position (see figure 1), plug the

unit into the wall outlet, and then turn it on.
3. Once proper AC wiring and grounding has been established via a green
"

Ground OK" light, unplug the unit, and plug the equipment to be

protected into the AC outlets on the unit.
4. Plug the protector in and turn it on.
5. One at a time, turn each piece of connected equipment

ON and check for

power and correct operation.
6. Turn

OFF the unit before installing any SurgeGate modules.

SURGEGATE M4KSU & SURGEGATE M8KSU

1. For AC connection, follow the steps in the SurgeGate 4KSU section.
2. Note the position of the LINE and EQUIP jack on the unit. LINE jack is for
the connection that comes from the wall or floor jack. EQUIP jack is for
the line connection to your connected equipment.
3.

For 8COM-60 / 8COM-5x9:

Plug the incoming telephone line into the “TEL” LINE jack (up to 5 “TEL”
LINE jack included).

For 8COM-60 / 8COM-5x9:

Plug the incoming T1/LL line into the “T1/LL” LINE jack.

For 8COM-60 / 4LAN:

Plug the incoming LAN line into the “LAN” LINE jack.
4. After connect the line between the wall and the unit, now plug…

A Phone into the “TEL” EQUIP jack or

A LAN cord into the “LAN” EQUIP jack or

A T1/LL cord into the “T1/LL” EQUIP jack.

Plug the other end into the equipment to be protected.
5. Turn

ON the unit and all equipment. Verify that each piece of equipment is

receiving power and signal.
6. Turn

OFF the unit before installing any SurgeGate modules.

SURGEGATE 4LAN, 8COM-60 & 8COM-5X9

Surges can get into your system from any metallic pathway
(wire) and from any direction. AC power lines, analog (voice)
lines, digital lines, data lines and even grounding wires can
carry a surge into your system and damage or destroy
system components. Make sure all pathways including AC,
digital, analog and data lines connected to your system pass
through the appropriate SurgeGate unit. This establishes a
common ground reference for the entire system per IEEE
recommendations. Failure to protect all lines/wires will
weaken the protection.

INCOMING

DATA

PHONE LINES

ANY OTHER

SIGNAL LINES

To properly

grounded

AC receptaccle

No other ground

AC

AC

AC

BU

BBL

E OF PROTECTION

No other wir

es or cables attached to equipment

KSU

PROTECTED

EQUIPMENT

BUBBLE OF PROTECTION—THE BASIC CONCEPT

www.itwlinx.com

Customer Service: 1-800-336-LINX (5469)

Part #: 2800-020-30I (Revision 2)

12/2009

Copyright® 2009 ITW Linx

The Power Protection indicator light is not lit, there is no AC power to my

equipment, or my equipment doesn’t turn on. What could be the problem?

• Make sure that the protector is plugged into a working AC outlet.

• Check all AC power connections.

• Make sure both the surge protector and connected equipment is turned on.

• Check to see if the circuit breaker on the surge protector needs to be

reset (press in).

FREQUENTLY ASKED QUESTIONS

The circuit breaker disconnects AC power from the connected

equipment. What could be the problem?

• You have exceeded the ampere rating for your surge protector. As a

temporary fix, disconnect one or more pieces of equipment. Call ITW

Linx Customer Service Department at 800-336-LINX for more information.

The length of any SurgeGate 4 is 9.5 inches; The length of any SurgeGate 8 is 13.5

inches. Dimensions include the mounting clips.
Hold the protector up to the wall where you want it mounted (the unit should be

mounted vertically).
1. Locate the two screw holes on the attached mounting plate (bottom of unit)
and single screw hole on the module connection plate.

EYELET

#6 SCREW

SIDE
VIEW
OF
WALL

EYELET
W/SCREW

2. Using the three screw holes as a
guide, drive three screws into the
wall as shown in diagram above.
3. Slide the protector onto the screws
to rest in place.

Figure 2

Wall Mounting Instructions:

Hold wall mounting template (provided) up to the wall where

you want the protector mounted. The protector can be mounted

vertically or horizontally. Using the appropriate screw center

points as a guide, drive two screws into the wall. Be sure to

leave a 1/8 inch gap between the screw head and the wall for

the protector to hang on. Slide the protector down onto the

screws to rest in place.

SLOTS FOR

HORIZONTAL

MOUNTING

SLOTS FOR

VERTICAL

MOUNTING

Properly Connecting Your Surge Protector.

To completely protect your equipment from power surges, every wire leading into

or out of the equipment you want to protect must be connected to the appropriate

surge protector. Damaging lightning and power surges can enter your system

through any AC power or signal line (phone lines, grounding wires, coaxial cables,

modem cables, etc.) connected to your electrical equipment. The surge protector

must also be plugged into a properly wired and grounded outlet.

Advertising