Trouble shooting – Metalfab 4P Series Vibrator User Manual

Page 5

Advertising
background image

5

*HIGH FORCE SETTINGS – AS SHIPPED WITH BOTH INSIDE AND
OUTSIDE ECCENTRICS ON BOTH ENDS OF VIBRATOR.

**LOW FORCE SETTINGS – REMOVE INSIDE ECCENTRIC ON BOTH
ENDS OF VIBRATOR. REMOUNT OUTSIDE ECCENTRIC AND LINE UP
NUMBER WITH ARROW ON SHAFT.

Trouble Shooting

A. VIBRATOR DOES NOT START:

1) Short in lines

2) Burned out overload protection

3) Short in winding, check with ohmmeter

B. VIBRATOR OVERLOAD POSSIBLE CAUSES:

1) Bolts holding vibrator are loose

2) Excessive ambient heat

3) One phase open (check: a) power source; b) wiring)

4) Bad bearings

Note:

Always make sure the data stamped on nameplate
corresponds to power sources.

WHEN INQUIRING ABOUT ANY VIBRATOR, ALWAYS REFER TO
THE SERIAL NUMBER STAMPED ON THE METALFAB NAMEPLATE.

Metalfab Service

Metalfab, Inc.

Prices Switch Road

P.O. Box 9

Vernon, NJ 07462

Phone (973) 764-2000

Fax (973)-764-0272

Email:

[email protected]

Advertising