PROBLEM

CAUSE

SOLUTION

Compressor will not run

Loss of power or overheating

No electrical power


Insufficient power from receptacle

Insufficient power from extension cord

Blown shop/house fuse

Shop/house breaker open

Amperage overload open



Pressure switch bad

Tank is full of air

Check for proper use of extension cord.

Check to be sure unit is plugged in. Check
fuse/breaker.

Use a receptacle on a different circuit.

Refer to chart on page 8 to choose an ap-
propriate extension cord.

Replace shop/house blown fuse.

Reset shop/house breaker, determining why
problem happened.

Move compressor to well-ventilated area.
Unit must be unplugged and allowed to cool
for 30 minutes to initiate reset.

Take compressor to service center.

Compressor will turn on when tank pressure
drops to cut-in pressure.

Motor hums but cannot run or
runs slowly

Low voltage

Wrong gauge wire or length of extension cord

Shorted or open motor winding

Defective check valve

Insufficient power from receptacle

Insufficient power from extension cord

Check with voltmeter.

Check for proper gauge wire and cord length.

Take compressor to service center.

Take compressor to service center.

Use a receptacle on a different circuit.

Refer to chart on page 8 to choose an ap-
propriate extension cord.

Amperage overload protector
cuts out repeatedly

Low voltage

Lack of proper ventilation/room temperature
too high


Wrong gauge wire or length of extension cord

Insufficient power from extension cord

Check with volt meter.

Move compressor to well-ventilated area.
Unit must be unplugged and allowed to cool
for 30 minutes to initiate reset.

Check for proper gauge wire and cord length.

Refer to chart on page 8 to choose an ap-
propriate extension cord.

Air tank pressure drops when
compressor shuts off

Loose connections (fittings, tubing, etc.)


Loose drain valve/open drain valve

Check valve leaking

Check all connections with soap and water
solution and tighten.

Tighten drain valve/close drain valve.

Take compressor to service center.

DANGER:

Do not disassemble check valve, tank
drain valve, or safety valve with air in
tank — bleed tank.

TROUBLESHOOTING