Menu setting table (4/6), 35 printer operation – CITIZEN CL-S521 User Manual

Page 35

Advertising
background image

35

Printer Operation

7 Zebra

®

Emulation

Top Menu

Sub Menu

Default

Menu

Remarks

Global

Config Set 1

Config Set 1

Sets the Config Set.

configuration

Config Set 2
Config Set 3

Page Setup

Print Speed

4 IPS

2 to 6 IPS

Printing speed setting
(2 to 4 IPS with optional peeler.)

Print Darkness

10

00 to 30

Print darkness setting
(printhead temperature)

Darkness Adjust

0

-10 to 10

Darkness command adjustment

Continuous Media

4.00 IN

0.25 to 32.00 IN

Setting default length of continuous media,

Length

101.6mm

6.40 to 812.8mm

if selected. ; the lower line is in metric mode.

Vertical Position

0.00 IN

-1.00 to 1.00 IN

Print start position adjustment

0.0mm

-25.4 to 25.4mm

Horizontal Shift

0.00 IN

-1.00 to 1.00 IN

Horizontal printing location adjustment

0.0mm

-25.4 to 25.4mm

Vertical Image Shift

000dots

-120 to 120 dots

Adjust the off set value in vertical when
mapping data on a RAM.

Media Sensor

See Through

See Through

Label sensor selection

Reflect
None

Small Media

OFF

ON

Setting for small labels

Adjustment

OFF

Small Media

1.00 IN

0.25 to 1.00 IN

Setting length of small label media

Length

25.4mm

6.40 to 25.4mm

System Setup

Sensor Level

1.5V

0.0V to 3.3V

Setting the threshold of the sensor

Paper End Level

2.80V

0.01V to 3.00V

Sets the paper end level.

Error Reporting

On Printing

On Printing

Setting for error report.

Immediate

Buzzer Select

ON

ON

Setting buzzer sounding conditions

OFF

Metric/Inch

Inch

Inch

Setting the units used

mm

Max Media Length

10.00 IN

1.00 to 50.00 IN

Setting the maximum label length

254.0mm

25.4 to 1270.0mm

Settings Lock

Off

On

When on, prevents software commands from

Off

changing the values set by the VuePrint menu

Keyboard Lock

Off

On

Prevents the control panel from affecting the

Off

printer's configuration. (User "lock-out")

Media Power Up

Off

On

Selects whether or not to initiate media

Off

measurement when the power in ON.

CI Lock

Off

On

Activates/deactivates the CI command.

Off

Emulation Select

ZPI2

DM4

Selects DataMax

®

/Zebra

®

compatibility

DMI

DM4: DataMax

®

400

DPP

DMI: DataMax

®

IClass

ZPI2

DPP: DataMax

®

Prodigy Plus

®

ZPI2: Zebra

®

Emulation

Emulation Auto

On

On

Selects the detection of Datamax

®

and

Detect

Off

Zebra

®

emulation.

Full Auto

Mode Settings

[Zebra

®

Emulation]

Advertising