US Balance US-EXCEL 500g x 0.1g User Manual

Us-excel - user manual

Advertising
background image

US-EXCEL - User Manual

Capacity: 500g x 0.1g - Weighing modes:

g, oz, gn, ct

Thank you for purchasing US-EXCEL digital scale. Please read all operation

instructions carefully before use.

Scales are precision instruments and should always be handled with proper

care. To ensure years of reliable service, keep these simple tips in mind:

• Do not exceed the scales maximum capacity. Overloading your scale can

permanently damage it!

• Avoid exposure to extreme heat or cold. Scales perform best at normal room

temperature. If temperatures have changed dramatically, recalibration may

be necessary.

• Allow your scale to acclimate to the room temperature for at least one hour

before use.

• Store your scale in a clean, dry location. Dust, dirt, and moisture can

accumulate on the weighing sensors and electronics causing inaccuracy or

malfunction.

• Avoid using you scale in close proximity to strong radio wave emitting

devices such as computers, cash registers, and cordless phones.

• Always weigh on a flat level surface, free from vibrations and drafts. The

corner of a room is usually the most stable.

• Gently apply all items to be weighed. Do not drop items onto the weighing

platform.

• Avoid dropping your scale. The warranty does not cover damage due to

rough treatment or overload.

I-

SPECIFICATION

Capacity

500g/17.64oz/321.5dwt/16.07ozt/7715gn/2500ct

Readability

0.01g/0.001oz/0.01dwt/0.001ozt/1gn/0.1ct

Units

g/oz/dwt/ozt/gn/ct

Tare range

Tare full capacity

Auto off

30 seconds

Operation temperature 50-86F

Display

LCD 5 ½ digits

Power

2 x AAA Batteries (Included)

Dimensions

3.74 x 2.16 x 0.62

I-

SCALE OPERATION

Place the Scale on a horizontal flat surface.

1. Press [ON/OFF] key.

2. Wait until “0.0” is displayed.

3. Put the object(s) on the weighing platform.

4. Using the MODE key, you can switch among the weighing units.

II-TARE WEIGHING

1. Turn on scale as described above.

2. Place the “Tare Item” on the platform.

3. Press [TARE] and wait until [0.0] is displayed.

4. Add the “net-weight-item”.

III-STANDARD CALIBRATION

1. When the scale is turned off, press [ON/OFF] key to turn on the scale until [0.0] is
displayed.
2. Press and hold the CAL key, until the display read [CAL] and then [500.0] will flash
on the LCD display.
3. Place a 500g weight on the center of the platform.
4. The LCD display reads [PASS] and then [500.0].
5. Remove the weight and press ON/OFF to turn off the scale. Finish!
Repeat this process if something was going wrong. Please check the availability of
weights at the store you bought your scale from.
V-TROUBLESHOOTING
The primary reasons for inaccuracy or malfunction are low batteries, incorrect

calibration, overload or operating on an unstable surface. Please keep this in mind

and maintain and operate your scale properly. The scale is a precise instrument and

must be handled with the utmost care and caution.

Display Elimination of errors

[LO]

Low battery, please replace the batteries.

[RECAL]

Recalibrate the scale as shown above

[EEEEE]

You are overloading the scale. Remove the excessive load

immediately!

[LLLLL]

The delicate weighing load cells have been damaged by misusing

the scale (i.e it was shocked, dropped or overloaded). You can try

recalibrating the scale, if the load cell has not been damaged too

much it will work again after recalibration.

[UNST]

Use the scale in a more stable position

Tested to comply with FCC standards