Waterworks Easton Classic Wall Mounted Extension Pot Filler, Metal Cross Handle User Manual

Installation guidelines, Easton pot filler

Advertising
background image

These guidelines have been prepared for the professional contractor to aid in the installation of:

EASTON POT FILLER (EAKM21)

All dimensions are based on original specification and are subject to change and variation.

Please consult your Design Associate for current specifications.

Installation Guidelines

W A T E R W O R K S

®

2/06

Easton Pot Filler

1

1

2

"

5

5

8

"

10"-13

1

2

"

2

3

8

"

5

7

8

"

8

1

2

"-12"

EAKM21

IMPORTANT

To ensure this product is installed properly, you

must read and follow these guidelines.

The owner/user of this product must keep this

information for future reference.

Be sure your installation conforms to local codes.

This product must be installed by a professional

contractor.

Inspect this product to assure you have all parts

required for proper installation.

Use only a strap wrench or protected/smooth-jaw

wrench on any finished surface

ROUGH IN:

1. Determine the ideal location of the faucet body

based on the clients preference.

2. Finish the rough in by installing a well supported 1/2"

NPT nipple. The face of the nipple should be
recessed ¼" behind the surface of the finished wall.

INSTALLATION:
3. Loosen the 2mm set screw (4) on the underside of

the valve body (3).

4. Pull the brass adapter (6b) out of the valve body then

using a 12mm hex wrench, thread the adapter onto

the NPT nipple.

5. Slide the escutcheon assembly (7-7b) back onto the

valve body, thread the faucet assembly onto the

adapter (6b) then tighten the set screw. Slide the
escutcheon toward the wall.

6. Remove the spout by unthreading the spout nut (5b)

then turn on the water to verify proper function.

7. Note that a primary filter screen is located inside the

spout nut (5b). A secondary filter screen is located
inside of the spout collar (5). To access the
secondary filter screen, unthread the spout collar and
pull off the front portion of the spout.

8. Remove filter screens and flush throughly.

9. To adjust the spout reach, simply pull/push the spout.

The spout reach can be locked at a fixed position by
tightening the spout collar (5).

10. To access the cartridge, unthread the handle

assembly (1-1h). Do not over-tighten the handle
assembly; hand tight is adequate. If this assembly is

too tight, the handle will bind.

If further assistance is required, please contact Product

Support at 1-800-927-2120 (8am-7pm EST).

Advertising