Waterworks .25 Pressure Balance Control Valve Trim with Metal Cross Handle User Manual

Installation guidelines, 25 pressure balance valve trim

Advertising
background image

Shower Outlet

2

1

8

1

4

"

Tub Outlet

Face of finished

wall

PTSV59 (trim) & GUSV81R (rough)

Installation Guidelines

W A T E R W O R K S

Waterworks is a registered trademark of Waterworks Inc.

04.11.07

.25 Pressure Balance Valve Trim

These guidelines have been prepared for the professional contractor to aid in the installation of:

.25 PRESSURE BALANCE VALVE TRIM (PTSV59 & GUSV81R) All dimensions are based on
original specification and are subject to change and variation. Please consult your Design Associate for
current specifications.

IMPORTANT

To ensure this product is installed properly, you
must read and follow these guidelines.

The owner/user of the valve must keep this

information for future reference.

The risk of scalding exists until the installer has

properly set the temperature high limit stop.

This product must be installed by a professional

contractor and conform to all applicable codes

Refer to the specification and assembly drawings

attached. Valves are sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.

If soldering any connections, remove cartridge to

prevent damage to seals.

This valve should be on-site prior to rough in and

allows the installer to visualize the installation.

Inspect this product to assure you have all parts

required for proper installation.

Check incoming water pressure; ideal operating

pressure is 40-50 PSI. The minimum is 20 PSI. and

the maximum is 100 PSI.

Designed for a rated supply pressure of 100 PSI and

a supply temperature from 40°-160° F.

Use only a strap wrench or protected/smooth-jaw

wrench on any finished surface.

ROUGH IN:

1. Make sure the valve body is positioned according to

valve markings so the inlets are situated with hot

piped on the left and cold piped on the right.

2. Remove and discard the wall mounting flange located

beneath the tile shield. The dome cover included will
not be used during the installation.

3. REQUIRED: Valve body rough-in depth is 2

1

8

" +/-

1

4

"

from the centerline of the supplies/inlets to the face

of the finished wall. Install so the back side of the
plaster shield contacts the finished wall as indicated
on the shield.

4. Run

1

2

" copper supply lines with a 5

1

2

" center spread

to the proper height of the valve inlets and be sure
to secure all piping and fittings.

5. Turn on the hot and cold supplies then check for

leaks.

VALVE OPERATION:

6. When the finished wall is complete, turn on the hot

and cold supplies and pull off the tile shield and
discard. Both supplies must be on or the valve will

not operate.

7. The handle (28) is for controlling temperature only,

not volume. Remove the 3mm hex set screw (27)

from the handle then slide the handle onto the

spindle (11).

8. Turn the handle counter clockwise through the cold

position then warm and stopping at the hot position.
If additional rotational friction is required to maintain

the handle position, tighten the packing nut (10).

9. Allow the valve to run in warm position for a few

minutes to completely flush the system. If system is
quite dirty, remove valve spindle to ensure proper

flushing.

10. IMPORTANT: This valve is equipped with a limit

stop screw (8) to be used to limit the valve handle

from being turned to excessively hot water discharge

temperatures.

5

7

8

"