These guidelines have been prepared for the professional contractor to aid in the installation of:

AMELIE THERMOSTATIC VALVE AND TRIM WITH CROSS HANDLE

(GUSV37R & AMSV68)
All dimensions are based on original specifications and are subject to change and variation.

Please consult your Design Associate for current specifications.

Installation Guidelines

Figure 1

1

GUSV37R (rough) + AMSV68 (trim)

Notes:
Rough-In depth: 2 ½” from the centerline of the inlets to the surface
of the finished wall. See Installation Guidelines for more information.
Inlets: ¾” female NPT
Ideal operating pressure: 50-60 psi
Maximum pressure 80 psi
Minimum pressure: 25 psi

.

..

..

5

2

1

3 x 2

1a

1b

4

Fig. 1a

6

IMPORTANT

1. To ensure this product is installed properly, you must

read and follow these guidelines.

2. The owner/user of the valve must keep this informa-

tion for future reference.

3. This valve includes integrated service stops. Make sure

the tile guard is in place.

4. This valve features anti scald protection.The risk of

scalding exists until the installer has properly

calibrated/adjusted the temperature setting during final

trim installation.

5. Valve body rough-in depth is 2 ½" the centerline of the

inlets to the face of the finished wall.

6. Be sure your installation conforms to local codes.

7. This thermostatic valve only mixes hot and cold water

and does not have volume control or shut off capability.

A diverter or wall valves (provided separately) control

on/off/volume and must be installed for each fitting that

will have water flowing to it.

8. This product must be installed by a professional contractor.

9. Refer to the specification and assembly drawings attached.

Valves are sold partially assembled but shown fully disas-

sembled for illustrative and service purposes only.

10. If soldering any connections, remove cartridge to

prevent damage to seals and internal assembly.

11. The trim should be on-site prior to rough in and allows

the installer to visualize the installation.

12. Inspect this product to assure you have all parts shown

that are required for proper installation.

13. Check incoming water pressure; ideal operating pressure is

50-60 psi. The minimum is 25 psi. and the maximum is 80 psi.

ROUGH IN:

14 . Make sure the valve body (1,1a) is positioned according

to valve markings so the inlets are situated with hot

piped on the left and cold piped on the right. Positioned

correctly, notice the inlets are below an imaginary

horizontal line drawn between the 2 cover screws (3).

15. IMPORTANT: Valve rough-in depth is 2-1/2 “measured

from the centerline of the inlets to the surface of the

finished wall.

16. . Run 3/4" copper supply lines to the proper height of the

valve inlets and be sure to secure all piping and fittings.