Waterworks Formwork Volume Control Valve Trim with Metal Lever Handle User Manual

Installation guidelines

Advertising
background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

FORMWORK
Volume Control Valve Trim

Installation Guidelines

Page 1 of 2

Rev - 01


4.7.2014

These guidelines have been prepared for the professional contractor to aid in the installation of:
FORMWORK VOLUME CONTROL VALVE TRIM WITH METAL KNOB HANDLES (STYLE No. FMVC01) &
FORMWORK VOLUME CONTROL VALVE TRIM WITH METAL LEVER HANDLES (STYLE No. FMVC10)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

STYLE No. FMVC01

STYLE No. FMVC10

with Metal Knob Handle

with Metal Lever Handle

SPECIFICATIONS:

Control Valve Rough-in Depth Min: 3-1/8"
Control Valve Rough-in Depth Max: 4-3/4"
Fittings Hole Diameter: Ø1-3/8"

REQUIRED PLUMBING DETAILS:

Universal 3/4" Volume Control Valve

STYLE No. GUVC16 (Hot Cartridge)

Universal 3/4" Volume Control Valve
STYLE

No. GUVC17 (Cold Cartridge)


IMPORTANT:

¾ To ensure this product is installed properly, you must

read and follow these guidelines. The owner/user of
this product must keep this information for future
reference.

¾ This product must be on-site prior to rough-in. This

allows the installer to visualize the installation and
verify the center spread.

¾ This product must be installed by a professional

licensed contractor. Be sure your installation conforms
to all federal, state, and local codes. In the State of
Massachusetts, all installations must comply with the
rules and regulations set forth within 248 CMR.

¾ Wall valves (SOLD SEPARATELY) control on, off and

volume and must be installed for each fitting that will
have water flowing to it. If using a wall valve with the
Universal 3/4" Thermostatic Valve (Style No.
GUTH37R - SOLD SEPARATELY), refer to the
Installation Guidelines for the Thermostatic Valve
which contains related installation information.

¾ Refer to the specification and assembly drawings

attached. Product is sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.

¾ Inspect the product to ensure you have all the parts

required for proper installation. Use only a strap
wrench or protected/smooth-jaw wrench on any
finished surface.

¾ DO NOT use putty. Putty contains oil and can cause

permanent discoloration on certain materials such as
marble, granite and any porous surface.

TRIM INSTALLATION:

1. Remove the TILE GUARD and the O-RING from the

VALVE as shown in Figure - 01.

FIGURE - 01

¾ See Figure - 02 for steps 2 & 3

DIMENSION VALUE

(INCHES)

A 1/2"
B 1/16"

FIGURE - 02

VALVE

O-RING

TILE GUARD

VALVE

O-RING

TILE GUARD

THREADED

TUBE

FINISHED WALL

CENTER OF

INLET

CENTER OF

INLET

CARTRIDGE

STEM

CARTRIDGE

"A"

CUT THREADED TUBE

BEHIND FINISHED WALL

"B"

CUT CARTRIDGE STEM

BEHIND FINISHED WALL

ROUGH-IN DEPTH

THREADED

TUBE

FINISHED WALL

CENTER OF

INLET

CENTER OF

INLET

CARTRIDGE

STEM

CARTRIDGE

Advertising
This manual is related to the following products: