Waterworks Henry Volume Control Valve Trim User Manual

Installation guidelines

Advertising
background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

HENRY

Volume Control Valve Trim

INSTALLATION GUIDELINES

Page 1 of 2


11.2.2012

These guidelines have been prepared for the professional contractor to aid in the installation of:
HENRY VOLUME CONTROL VALVE TRIM WITH METAL CROSS HANDLE (STYLE# HNVC40) &
METAL LEVER HANDLE (STYLE # HNVC50)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
SEE SERVICE PART DOCUMENT FOR PART ORDERING, AVAILABLE ON WATERWORKS.COM

Metal Cross Handle
Style No. HNVC40
Code No. HNSV40

Metal Lever Handle
Style No. HNVC50
Code No. HNSV50

SPECIFICATIONS:
Fitting Hole Diameter: 1-3/8"

Volume Control Valve Rough-In Depth:

GUVC16 or GUVC17: 2-3/8" MIN - 3-3/8" MAX


2-Way or 3-Way Diverter with Shutoff Valve Rough-In
Depth (For Thermostatic Systems):

GUDV14 or GUDV66: 2-1/2" MIN - 4-1/8" MAX


2-Way or 3-Way Diverter without Shutoff Valve Rough-
In Depth (For Pressure Balance Systems)::

GUDV23 or GUDV65: 3-1/8" MIN - 3-5/8" MAX


REQUIRED PLUMBING DETAILS:
Universal 3/4" Volume Control Valve (Clockwise Close)

STYLE No. GUVC16
CODE No. GUSV16R

Universal 3/4" Volume Control Valve (Counterclockwise
Close)

STYLE No. GUVC17
CODE No. GUSV17R

Universal 2-Way Diverter with Shutoff Valve

STYLE No. GUDV14
CODE No. GUSV14R

Universal 2-Way Diverter without Shutoff Valve

STYLE No. GUDV23
CODE No. GUSV23R

Universal 3-Way Diverter with Shutoff Valve

STYLE No. GUDV66

Universal 3-Way Diverter without Shutoff Valve

STYLE No. GUDV65

IMPORTANT:

¾

To ensure this product is installed properly, you

must read and follow these guidelines.

¾

The owner/user of this product must keep this

information for future reference.

¾

Be sure your installation conforms to federal state,

and local codes. In the State of Massachusetts, all
installations must comply with the rules and
regulations set forth within 248 CMR.

¾

This product must be installed by a professional

licensed contractor and must be onsite prior to
rough-in, this allows the installer to visualize the
installation.

¾

Wall valves control on/off/volume and must be

installed for each fitting that will have water flowing
to it. If using a wall valve with the Universal 3/4"
Thermostatic Valve (Style No. GUTH37R), refer to
the Installation Guidelines for the Thermostatic
Valve which contains related installation information.

¾

Inspect this product to ensure you have all the parts

required for proper installation.

¾

Use only a strap wrench or protected/smooth-jaw

wrench on any finished surface.

¾

DO NOT use putty on fittings.

CONTROL VALVE TRIM INSTALLATION WITH VOLUME

CONTROL VALVES GUVC16R/17R:

¾

See Figure - 01 for steps 1 & 2

1.

Pull the tile guard off the threaded sleeve from the
wall valve rough. Mark the threaded sleeve at the
finished wall. Unthread the sleeve and cut 1/2" in
front of the mark.

2. Mark the cartridge stem at the wall, then unthread

the cartridge from the valve body. Cut the cartridge
stems 1-3/8" in front of the mark.

3. After the cuts have been made, thread cartridge and

handle sleeve back onto valve body.

Advertising