8. Allow the valve to run in warm position for a few

minutes to completely flush the system. If system is
quite dirty, remove valve spindle to ensure proper

flushing.

9. IMPORTANT: This valve is equipped with a limit

stop screw (8, 9) to be used to limit the valve handle
from being turned to excessively hot water discharge

temperatures.

10. Setting the limit stop screw : Open the valve to the

maximum desired temperature then turn the limit
stop screw (8) in until it seats.

11. WARNING: FAILURE TO ADJUST THE LIMIT

STOP SCREW PROPERLY MAY RESULT IN
SERIOUS SCALDING.

12. WARNING: THIS SHOWER SYSTEM MAY NOT

PROTECT THE USER FROM SCALDING WHEN

THERE IS A FAILURE OF OTHER TEMPERATURE

CONTROLING DEVISES ELSEWHERE IN THE

PLUMBING SYSTEM.

INSTALL THE TRIM:
Note: Part numbers refer to trim and/or rough

exploded view drawings.

13. Hand tighten the dome cover (5) completely onto

the packing nut (10). The dome cover MUST be
tightened to prevent damage to the handle.

14. Moisten the o-ring (7a) then slide the plate (7-7b)

trim over the dome cover.

15. Secure the plate to the wall using the two screws

(6).

16. Pull off the indice assembly (2-2c) from the handle,

position then hold handle spacer (4) onto the
spindle. Secure the handle by tightening the screw
(3) then reinstall the indice assembly.

Installation Guidelines

W A T E R W O R K S

Waterworks is a registered trademark of Waterworks Inc.

SERVICE

NOTE: REFER TO EXPLODED VIEW DRAWING
FOR SERVICE PART CALL OUTS. A TROUBLE

SHOOTING GUIDE IS ALSO INCLUDED.)

18. Remove valve trim.

19.Shut-off water to the valve. Remove the service

stop cap (26), stop retainer (25) and tighten valve
stop (22) with a

3

16

" hex wrench.

20.CAUTION: Before removing main cap/bonnet nut

(3) use the following sequence to avoid damage to

the stem:

-Unthread the adjustment screw (9) until the o-ring

is fully exposed.

-Open valve to full hot and unscrew cap/bonnet nut

(3).

Leave packing nut (10) in place when removing

cap/bonnet nut to avoid damage to packing
assembly.

-Control stem/spindle (11-13) will be removed with

the cap/bonnet nut.

21.Replace appropriate parts as needed and inspect

seats and o-rings for any visible wear.

22.Extended Service:

-Control Stem: the end of the control stem that is

the furthest point into the valve is the most

important part. This houses the stainless steel

control piston (12).

-Shake the stem and listen for the piston to be

moving back and forth. A freely moving piston
makes a knocking noise similar to an empty spray
paint can.

-If a noise is not detected, check for obstructions

such as flux, solder, saw dust etc. Soak in de-scaler is
necessary.

-Replace the cartridge if the piston does not move

freely.

-Seat replacement: requires seat replacement tool

and appropriate parts.

23.Reinstall the valve in reverse sequence.

If further assistance is required, please contact Product

Support at 1-800-927-2120 (8am-7pm EST).

Julia Pressure Balance Valve Trim

17. Open the valve and confirm the temperature

setting, adjust as required.

10.09.06

These guidelines have been prepared for the professional contractor to aid in the installation of:

JULIA PRESSURE BALANCE VALVE TRIM (JUSV31-K, JUSV32-K, JUSV33-K

& GUSV81R) All dimensions are based on original specification and are subject to change and variation.

Please consult your Design Associate for current specifications.

Advertising