Installation Guidelines

W A T E R W O R K S

Waterworks is a registered trademark of Waterworks Inc.

10.06.06

Shower Outlet

2

3

8

1

2

"

Tub Outlet

Julia Pressure Balance Valve Trim with Diverter

IMPORTANT

To ensure this product is installed properly, you must

read and follow these guidelines.

The owner/user of the valve must keep this

information for future reference.

The risk of scalding exists until the installer has

properly set the temperature high limit stop.

This product must be installed by a professional

contractor and conform to all applicable codes

Refer to the specification and assembly drawings

attached. Valves are sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.

If soldering any connections, remove diverter

assembly and cartridge to prevent damage to seals.

This valve should be on-site prior to rough in and

allows the installer to visualize the installation.

Inspect this product to assure you have all parts

required for proper installation.

Check incoming water pressure; ideal operating

pressure is 40-50 psi. The minimum is 25 psi. and the
maximum is 80 psi.

Use only a strap wrench or protected/smooth-jaw

wrench on any finished surface.

ROUGH IN: (GUSV87R ROUGH SOLD
SEPARATELY):

IMPORTANT - remove cartridge (11-14) and

diverter assembly (27-30) when soldering any
connections. Failure to remove the cartridge and
diverter will damage both assemblies.

1. Install rough piping and valve body as shown.

-Refer to marking on valve body when installing. When

facing valve, HOT 'H" is on the left and COLD 'C' is

on the right.

-Valve should be installed with the plastic tile guard

lettering face flush with the finished wall.

2. Tile finished surface of wall, be careful to keep all ports

free of obstructions.

3. Turn on the hot and cold supplies and flush out the

valve.

-Valve will not operate unless both hot and cold water
are turned on.
-Allow valve to run in warm position for a few minutes

to totally flush the system.

IF SYSTEM IS EXCESSIVELY DIRTY, REMOVE THE

CARTRIDGE (11-14) ASSEMBLY TO ENSURE
PROPER FLUSHING.

4. Tighten packing nut (10) for desired rotational

resistance in handle.

VALVE OPERATION:

5. When the finished wall is complete, open the hot and

cold supplies. The supplies are opened by removing

the service stop cap (26) and stop retainer (25) then
turning the

3

16

" hex screw (22) counter clockwise.

Both supplies must be on or the valve will not

operate.

6. Pull off the tile shield and discard.

7. The larger of the two handles is for controlling

temperature only, not volume. The smaller handle is

used to divert the water in a tub and shower
combination and cannot be used to supply water to a
handshower. Install the large handle (1-1f) so it rests
at 6 o-clock in the OFF position then turn the handle
counter clockwise through the cold position then

warm and stopping at the hot position. If additional

rotational friction is required to maintain the handle
position, tighten the packing nut (10).

These guidelines have been prepared for the professional contractor to aid in the installation of:

JULIA PRESSURE BALANCE VALVE TRIM WITH DIVERTER (JUSV41-K, 42-K, 43-K &

GUSV87R) All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

JUSV41-K (metal lever handle) & GUSV87R (rough)

JUSV42-K (white porcelain lever handle) & GUSV87R (rough)

JUSV43-K (black porcelain lever handle-MTO) & GUSV87R (rough)

Surface of finished

wall

5

7

8

"

3