Waterworks Easton Classic Three Cross Handle Exposed Thermostatic System with Shower Rose and Handshower User Manual

Installation guidelines

Advertising
background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

EASTON CLASSIC
Exposed Thermostatic System with 8" Shower Rose

Installation Guidelines

Page 1 of 3

Rev - 01


11.11.2013

These guidelines have been prepared for the professional contractor to aid in the installation of:
EASTON CLASSIC EXPOSED THERMOSTATIC SYSTEM WITH 8" SHOWER ROSE (STYLE No. EAXS42) &
EASTON CLASSIC EXPOSED THERMOSTATIC SYSTEM WITH 8" SHOWER ROSE AND HANDSHOWER
(STYLE No. EAXS52)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

STYLE No. EAXS42

STYLE No. EAXS52

with Handshower

SPECIFICATIONS:

Fittings Hole Diameter: Ø1-1/4"
Inlet Connection Size & Type: 3/4" Male NPT
Inlet Supply Spread: 8-1/8" (NOT ADJUSTABLE)
Recommended Water Pressure: 45psi
Restricted Maximum Flow Rate: 2.5 gpm
Water Pressure Range: 20psi MIN - 80psi MAX

IMPORTANT:

¾ To ensure this product is installed properly, you

must read and follow these guidelines. The
owner/user of this product must keep this
information for future reference.

¾ This product must be installed by a professional

licensed contractor. Be sure your installation
conforms to all federal, state, and local codes. In
the State of Massachusetts, all installations must
comply with the rules and regulations set forth
within 248 CMR.

¾ This product must be on-site prior to rough-in.

This allows the installer to visualize the
installation and verify the center spread.

¾ Refer to the specification and assembly drawings

attached. Product is sold partially assembled but
shown fully disassembled for illustrative and
service purposes only. Inspect the product to
ensure you have all the parts required for proper
installation.

¾ Use only a strap wrench or protected/smooth-

jaw wrench on any finished surface. DO NOT use
putty. Putty contains oil and can cause
permanent discoloration on certain materials
such as marble, granite and any porous surface.

¾ Check incoming water pressure and install

accessible hot and cold service stop valves to
facilitate servicing.

¾ The risk of scalding exists until the installer has

properly calibrated the temperature setting.

ROUGH-IN:

1. Considering ceiling clearance and proper shower

rose height, determine the ideal location for the
product based on user preference.

2. Run well supported 3/4" hot and cold copper

supply lines for maximum water flow. The spread
between supplies is 8-1/8" on center and is NOT
adjustable. Verify the supplies are secure, level,
at the proper spread of 8-1/8" and equal depths.
Install blocking to properly secure the shower
arm bracket.

3. Install temporary 3/4" NPT nipples (not

included), cap off the supplies and check for
leaks.

INSTALLATION:

4. Remove the temporary nipples. Thread on the

NPT end of the plated nipples provided to create
a proper seal and securely tighten. The nipples
must protrude 7/8" to 2" from the finished wall.
Verify the supplies are secure, level, at the
proper spread of 8-1/8" and equal depths.

7/8" MIN

2" MAX

PROJECTION FROM

FINISHED WALL

8-1/8"

7/8" MIN

2" MAX

PROJECTION FROM

FINISHED WALL

8-1/8"

Advertising