Installation guidelines – Waterworks Etoile Flare Concealed Tub Filler Without Handshower and Ebony Lever Handles User Manual

Page 2

Advertising
background image

Etoile Wall Mounted Flared Spout Tub Filler

HANDLE INSTALLATION:

9. Unthread the 3 screws (14a) that secure the soap dish

(14) to the valve trim and remove the soap dish.

10. Pull the tile shield off the threaded sleeves (3) then

slide the trim (13) up tight to the wall. Verify general
alignment of the trim in relation to the rough.

11. Hand tighten the flat escutcheon (17,17a) then handle

assembly (16-16g) onto the threaded sleeve until both

will not thread further.

12. Measure the distance from the face of the flat

escutcheon to the face of the bell escutcheon (16d).

This measurement will be the length of threaded sleeve
that will be cut off in step 14.

13. Remove the handle assembly, escutcheon, and

threaded sleeve.

14. Mark then cut the threaded sleeve the amount equal

to what was measured in step 12. Do NOT cut the

end of the threaded sleeve (3) that has internal threads.

15. Thread the threaded sleeve back onto the valve

stem/cartridge (2) and mark the valve stem at a point

that is

1

2

" BEYOND the end of the threaded sleeve.

16. Remove the threaded sleeve and valve stem then cut

the valve stem at the mark made in step 15.

17. Reinstall the valve stem/cartridge (2) then the threaded

sleeve (3) and make sure the stem tip is

1

2

" beyond the

end of the sleeve. Adjust/cut the stem or sleeve as
needed.

Installation Guidelines

W A T E R W O R K S

Waterworks is a registered trademark of Waterworks Inc.

.

SPOUT INSTALLATION:

18. IMPORTANT: Cut the copper pipe exactly 3" beyond

the finished wall

19. Unpack the spout and verify the spout adapter (11) is

threaded completely into the spout.

20.To verify alignment of the spout and adapter, make a

mark at 12:00 that extends from the spout (15) onto

the adapter (11).

21.Unthread the spout adapter from the spout then slide

the adapter onto the copper pipe so the face of the

adapter is flush with the copper pipe. The copper pipe
must not protrude past the face of the adapter.

22.After verifying fit, make sure the mark made in step 20

remains at 12:00 then sweat the adapter onto the
copper pipe (10-not supplied). If it is not aligned, the
spout will not thread on completely and cause a leak or
not align properly so the spout tip points down at 6:00.

23.Allow the adapter (11) to cool then wrap it with Teflon

tape.

FINAL TRIM INSTALLATION:

24.Secure the trim (13) to the wall using the 2 screws

(13a) provided.

25.Reattach the soap dish.

28.Verify installation and function of the valve.

If further assistance is required, please contact Product

Support at 1-800-927-2120 (8am-7pm EST)

26.Thread the flat escutcheons onto the threaded sleeves

to secure the trim to the wall then thread the handles

onto the threaded sleeves (3).

09.15.06

27.Make sure the washer (12) is fully inserted into the

spout (15) then thread the adapter into the spout.

These guidelines have been prepared for the professional contractor to aid in the installation of:

ETOILE WALL MOUNTED FLARED SPOUT TUB FILLER (ETTU45 & GUSV90ET)

All dimensions are based on original specification and are subject to change and variation. Please
consult your Design Associate for current specifications.

Advertising