Waterworks Easton Vintage Exposed Tub Filler with Cross Handles and Handshower with White Porcelain Lever Diverter and White Porcelain Lever Handles User Manual

Installation guidelines

Advertising
background image

➢ Refer to the specification and assembly drawings attached.

Faucet is sold partially assembled but shown fully
disassembled for illustrative and service purposes only.

➢ Inspect this product to assure you have all parts required for

proper installation.

➢ Use only a strap wrench or protected/smooth-jaw wrench

on any finished surface.

➢ Install accessible hot and cold service stop valves to facilitate

servicing.

ROUGH IN:
1. Run

3

/

4

" hot and cold supply lines for maximum water flow.

The spread between supplies is 7-

1

/

4

" and is NOT adjustable.

2. Install a well supported

3

/

4

" sweat x

3

/

4

" female IPS elbow

onto each supply line.The distance from the face of the
elbow to the surface of the finished wall m

mu

usstt b

be

e

1

1

//

2

2

"" ffo

orr

o

op

pttiim

mu

um

m p

prro

ojje

eccttiio

on

n iin

ntto

o tth

he

e ttu

ub

b..

3. Verify the elbows are secure, level, at the proper spread of

7-

1

/

4

", and equal depths.

4. Stub-out

3

/

4

" capped nipples to allow for finished wall

installation and then turn on the supplies and check for leaks.

TUB FILLER INSTALLATION:
5. After the finished wall is complete, remove the nipples

installed in step 4.

6. Apply thread compound to the longer of the 2 threaded

sections of the wall union (2).

7. Thread the wall union into the

3

/

4

" elbow and tighten using a

17mm hex wrench.

8. Slide an escutcheon (3,4) onto the union. If desired, a bead

of caulk of silicone may be applied where the escutcheon
contacts the wall.

9. Install a

3

/

4

" washer (1) into each inlet and then attach the

tub filler to the wall unions by tightening the nuts (22) on
the back side of the tub filler.

10.Insert a

3

/

4

" washer (19) into the base of the cradle (11) and

then secure the cradle to the tub filler by tightening the nut
(11a). Cradle can be positioned with hose outlet pointing to
the left or the right.

Easton

®

Exposed Tub Filler with wall unions

These guidelines have been prepared for the professional contractor to aid in the installation of:
EASTON

®

EXPOSED TUB FILLER (EATU21,22-K,24-K,25-K,31,32-K,34-K,35-K)

EASTON

®

WALL UNIONS (EATU18)

All dimensions are based on original specifications and are subject to change and variation.
Please consult your Design Associate for current specifications.

Installation Guidelines

1

W A T E R W O R K S

®

12/03

(Covered Escutcheon)
EATU21(White porcelain handles and indices) EATU18(Wall Unions)
EATU22-K(Metal handles and indices)
EATU24-K(Black porcelain handles and metal indices)
EATU25-K(Oak handles and metal indices)

7

1

/

4

"

6

3

/

4

" to 8"

1

1

/

4

"

max

4

1

/

2

"

5

3

/

8

"

9"

Notes:

3

/

4

" male NPT inlets

• Spread is NOT adjustable
• Check tub deck and tub measurements to assure
the spout projects far enough into the tub
• Anti scald protections is the responsibility of the
installer and according to applicable codes
• Replacement cartridge - part # WWPTU11

EATU21-25-K

(Uncovered Escutcheon)
EATU31(White porcelain handles and indices)
EATU32-K(Metal handles and indices)
EATU34-K(Black porcelain handles and metal indices)
EATU35-K(Oak handles and metal indices)

INSTALLATION GUIDELINES:

IMPORTANT:

➢ T

To

o e

en

nssu

urre

e tth

hiiss p

prro

od

du

ucctt iiss iin

nssttaalllle

ed

d p

prro

op

pe

errllyy,, yyo

ou

u m

mu

usstt rre

eaad

d aan

nd

d

ffo

ollllo

ow

w tth

he

esse

e ggu

uiid

de

elliin

ne

ess..

➢ T

Th

he

e o

ow

wn

ne

err//u

usse

err o

off tth

he

e ttu

ub

b ffiilllle

err m

mu

usstt kke

ee

ep

p tth

hiiss iin

nffo

orrm

maattiio

on

n ffo

orr

ffu

uttu

urre

e rre

effe

erre

en

ncce

e..

➢ Be sure your installation conforms to federal, state, and local

codes. Anti scald protection is the responsibility of the installer
and according to applicable codes.

➢ This tub filler should be on-site prior to rough in and allows the

installer to visualize the installation and verify the center spread.

➢ Check tub deck and tub measurements to assure the spout

projects far enough into the tub.

Advertising