Waterworks Ludlow Deck Mounted Exposed Tub Filler with Handshower and Metal Lever Handles User Manual

Installation guidelines

Advertising
background image


LUDLOW

Exposed Deck Mounted Tub Filler With Handshower

INSTALLATION GUIDELINES

Page 1 of 2

4.30.2014

These guidelines have been prepared for the professional contractor to aid in the installation of:
LUDLOW EXPOSED DECK MOUNTED TUB FILLER WITH HANDSHOWER WITH METAL CROSS
HANDLES (STYLE# LDXT40) & METAL LEVER HANDLES (STYLE# LDXT50)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

Metal Cross Handles
Style No. LDXT40

Metal Lever Handle
Style No. LDXT50

SPECIFICATIONS:
Handle Spread: 8" (NOT ADJUSTABLE)
Inlet Connection Size: 3/4"
Inlet Connection Type: Male NPT
Inlet Connection Spread 8" (NOT ADJUSTABLE)
Maximum Water Pressure: 80psi
Minimum Water Pressure: 20psi
Fittings Hole Diameter: 1-1/4"
Recommended Water Pressure: 45psi
Spout Reach: 8-9/16"

IMPORTANT:

¾ To ensure this product is installed properly, you

must read and follow these guidelines.

¾ The owner/user of this product must keep this

information for future reference.

¾ Be sure your installation conforms to federal state,

and local codes. Anti-scald protection is the
responsibility of the installer and according to
applicable codes.

¾ In the State of Massachusetts, all installations must

comply with the rules and regulations set forth
within 248 CMR.

¾ This product must be installed by a professional

licensed contractor.

¾ Product should be on-site prior to rough-in. This

allows the installer to visualize the installation and
verify the inlet connection spread.

¾ Refer to the specifications and assembly drawings

attached. Product is sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.

¾ Check tub measurements to assure the spout

projects far enough into the tub.

¾ Inspect this product to ensure you have all the parts

required for proper installation.

¾ Use only a strap wrench or protected/smooth-jaw

wrench on any finished surface.

¾ Run 3/4" supply lines for maximum flow.

¾ Install accessible hot and cold service stop valves to

facilitate servicing.

ROUGH-IN:

1.

Run well supported 3/4" hot and cold supply lines
for maximum water flow. The inlet supply spread is
8" on-center and is not adjustable. 1-1/4" drilling for
the mounting holes is recommended.

TUB FILLER INSTALLATION:

¾ See Figure 1. for Steps 2-5.

2. Rotate the SPOUT, so that it is facing forwards and

then tighten the SET SCREW.

3. Remove the NUT and FIBER WASHER from SHANK.

4. Place both SHANKS of the TUB FILLER through

both holes in the deck, while holding
ESCUTCHEONS.

5. Re-install FIBER WASHER and NUT to SHANKS to

secure assembly.

Figure 1

TUB FILLER

ASSEMBLY

FIBER WASHER

NUT

8"

ESCUTCHEON

SHANK

SPOUT

SET SCREW

Advertising
This manual is related to the following products: