Waterworks Universal Three Way Diverter Valve without Shutoff for Pressure Balance Shower Systems User Manual

Installation guidelines

Advertising
background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

UNIVERSAL
Three Way Diverter Valve For Pressure Balance Shower Systems

Installation Guidelines

Page 1 of 2

Rev - 05


6.16.2014

These guidelines have been prepared for the professional contractor to aid in the installation of:
UNIVERSAL THREE WAY DIVERTER VALVE FOR PRESSURE BALANCE SHOWER SYSTEMS
STYLE No. GUDV65, GU65DV (UK).
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

STYLE No. GUDV65†

SPECIFICATIONS:

Fitting Hole Diameter

Ш2 1/2" * (Ш 63.5mm)

Inlet Connection Size &
Type:

1/2" Female NPT†

Outlet Connection Size &
Type:

1/2" Female NPT†

Recommended Water
Pressure:

45 psi (3 Bar)

Unrestricted Maximum
Flow Rate:

16.9gpm @ 45 psi
(64 L/min @ 3 Bar)

Valve Material:

Ceramic

Water Pressure:

20 psi MIN - 80psi MAX
(1.4 Bar Min - 5.5 Bar Max)

* Ø2 1/2" hole is required for servicing the valve

† UK Style No. GU65DV supplied with 4 BSP Adapters,
assembly required.

REQUIRED PLUMBING DETAILS:
Universal Three Way Pressure Balance Diverter Valve
Trim
STYLE

No.

UNDV3P

Universal Pressure Balance Valve

STYLE No. GUPB81 or,

Universal Pressure Balance with Diverter Valve

STYLE No. GUPB87


IMPORTANT:
¾ To ensure this product is installed properly, you must

read and follow these guidelines. The owner/user of
this product must keep this information for future
reference.


¾ This product can only be used with either the Universal

Pressure Balance Valve (GUPB81) or the Universal
Pressure Balance with Diverter Valve (GUPB87). This
product requires a compatible wall valve trim and trim
plate. ALL PRODUCTS SOLD SEPARATELY.

¾ This product, the pressure balance valve (GUPB81 or

GUPB87) and the associated trims must be on-site
prior to rough-in. This allows the installer to visualize
the installation.

¾ Inspect this product to assure you have all the parts

required for proper installation.

¾ Refer to the specification and assembly drawings

attached. Product is sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.

¾ This product must be installed by a professional

licensed contractor. Be sure your installation conforms
to all federal, state, and local codes. In the State of
Massachusetts, all installations must comply with the
rules and regulations set forth within 248 CMR.

¾ Check incoming water pressure.

FUNCTION:

¾ The Universal Pressure Balance Valves (GUPB81 and

GUPB87) control on/off and mix hot and cold water.
Mixed water flows out at a fixed volume to the
diverter valve (GUDV65) which has 3 positions/outlets
to direct water flow to a maximum of 3 devices:
Shower head, handshower and secondary shower
head. Water cannot flow out of the devices
simultaneously (i.e. out of the shower head and
handshower together). The GUDV65 can only be
connected to the top outlet port of the GUPB81 and
GUPB87. The GUPB87 features an integrated diverter
for use with a tub spout that does not have a built in
diverter.

ROUGH-IN:
¾ Valve rough-in depth is measured from the centerline

of the inlets to the surface of the finished wall and
varies depending on the trim being used.

ROUGH-IN CHART

GUPB81/87 GUDV65

Trim Min

Max

Min

Max

.25, Flyte,
Henry, Opus,
R.W. Atlas

2 3/8"

(60mm)

2 7/8"

(73mm)

3 1/8"

(79mm)

3 5/8"

(92mm)

Formwork

2 1/4"

(57mm)

2 5/8"

(67mm)

3"

(76mm)

3 3/8"

(86mm)

Ludlow

2 1/8"

(54mm)

2 7/8"

(73mm)

2 7/8"

(73mm)

3 5/8"

(92mm)

All Other

1 7/8"

(48mm)

2 7/8"

(73mm)

2 5/8"

(67mm)

3 5/8"

(92mm)

DIVERTER

VALVE

PRESSURE BALANCE

VALVE

FINISHED WALL

CENTER OF

INLET

CENTER OF

INLET

ROUGH-IN

DEPTH

ROUGH-IN

DEPTH

Advertising