6.7 Alarm Menu

The Alarm menu is located on the right of the Settings screen. When you click on the word “Alarm”, a sub-menu of
alarm setup options will be displayed.

6.7.1 Digital I/O Setup

Applies to products: YCBL03, YCBLB3, YCEB03, YCBLHD5

This menu refers to the Digital I/O found on the Y-cam Breakout Box.

The 4-pin I/O terminal connector provides the interface to: 1 digital input, 1 digital output, auxiliary power and GND
(ground)

Some versions of the Y-cam Bullet may be supplied with the attached Digital I/O connector:

Pin

Function

Description

4

GND

Common Ground

3

Digital Input

Connect to GND to activate, or deactivate by software setting.

2

Digital Output

With a maximum load of 1A and maximum voltage of 60VDC, this output uses an open-
collector NPN Darlington transistor with the emitter connected to the GND pin. If used
with an external relay a diode must be connected in parallel with the load for protection
against voltage transients.

1

Auxiliary DC Power

12V DC max. Electrically connected in parallel with the connector for the PS-L power
adapter, this pin provides an auxiliary connector for power to the unit. This pin can also
be used to power auxiliary equipment, max 40mA.