CLEANING & SANITIZING (PERFORM DAILY OR AS DIRECTED BY YOUR PRODUCT SUPPLIER)

Use a concentrated cleaning solution to simplify the cleaning procedure. This procedure requires a one gallon container of a cleaning solution

containing hot water and a granulated concentrated cleaner (a cleaner like Coffee Dispenser Cleaner Corporation #12580, Urnex or equivalent)

and a one gallon container of clean hot water.

1. Turn on water supply to the dispenser.
2. Remove the quick disconnect from

the tea concentrate bag.

3. Pull the cap off of the QCD (see detail

drawing) and place this end of the

line into the container containing the

cleaning solution.

4. Place a large empty container under

the dispenser faucet.

5. Open the front faucet and dispense at

least half of the cleaning solution.

6. Allow the dispenser to sit overnight

before flushing cleaning solution.

7. Flush the system by filling a one gal-

lon container with clean hot water (no

cleaning solution) and open the faucet

and dispense at least one gallon of the hot water or until all the cleaning

solution has been flushed from the system.

8. Remove the QCD from the flushing container and replace the cap. Reconnect

the QCD to the Bag in the Box tea concentrate and dispense several cups to

prime the concentrate line or until consistency of the product is correct.

SANITIZING

Use a Bag-in-Box style cleaning solution to simplify the sanitizing procedure. A product like BevClean (http://bevclean.

com) beverage line sanitizer comes in a 3 gallon bag-in-box that connects directly to your bag-in-box system for line

sanitizing.

1. Remove the quick disconnect from the tea concentrate bag.
2. Place the BIB sanitizer container next to the TCC tea dispenser. Pull the spout from the sanitizer box through

the marked area. Remove the clear travel cap from spout. Don’t worry about spilling sanitizer when the cap is

removed. The cap has an internal seal.

3. Snap the QCD bag connector onto the bag spout.
4. Grasping the bag connector (as shown in Load Product, step 6), push the sliding probe all the way into the bag

spout. A “click” will be heard when it is fully inserted.

5. Once the cleaning solution box is connected, open the dispensing valve on the dispenser and run liquid through

the valve until the sanitizer (clear liquid) is detected.

DO NOT FLUSH. Allow the sanitizing solution to sit in the tea lines overnight before proceeding

with line flushing steps 6 through 8, below.

6. Remove the QCD from the BIB cleaner. Unsnap the connector probe, pulling out and removing the connector

from the spout.

7. Flush the line with warm water to remove any cleaning solution.
8. Reattach the tea concentrate BIB product.
9. Open the dispensing faucet in front of the dispenser and allow water to run out until tea flows from the faucet.

10. Repeat the process for any additional faucets on dispenser.
Note: Muliti-outlet manifolds are available for sanitizing up to eight beverage lines with one bag-in-box sanitizer. This

allows you to clean all systems at one time.