TIMER SETTING – DHG

1. To set the timer, place an empty filter paper below the chute. Pour whole bean coffee

into the hopper.

2. Open the lower cover to reveal the timer.
3. On the timer control board, locate the programming switch. Switch from RUN to PROG

(see illustration, left).

4. On the front cover, select the desired switch to program, REGULAR or DECAF. Press

and hold this switch.

5. The grinder motor and auger motor will start grinding coffee. When the desired ground coffee output is reached,

release the grind switch. The auger motor will shut off, stopping the flow of coffee from the hopper. The grind motor

will continue to run until the delay has elapsed.

6. Move the program switch to RUN. This will save the time setting.
7. Repeat steps 1 to 6 for the other grind switch.

TIMER SETTING SHG

1. Take off timer cover, located behind hopper. Remove the four screws holding

the cover in place. The timer is found inside this cover. Also refer to the illus-

trated parts diagram on page 3.

2. The timer controls are a high/low switch and a dial with a corresponding scale.

The switch allows you to select a scale on the dial. The outside scale range

is ½ second through 15 seconds. The inside scale range is 2 seconds to 60

seconds.

3. Test a new adjustment by grinding some coffee. When the results are satisfac-

tory, reinstall timer cover.