Wilbur Curtis WB5NLB User Manual

Service manual – wb5n hot water dispenser

Advertising
background image

1

Important Safeguards/Symbols

Models Included

• WB5N

• WB5NL

• WB5N30

• WB5NB

• WB5NLB

Service Manual – WB5N Hot Water Dispenser

W

ilbur

C

urtis

C

ompany

, i

nC

.

Symbols:

WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements

This equipment is designed for commercial use. Any servicing other than cleaning and routine

maintenance should be performed by an authorized Wilbur Curtis Company service technician.

• DO NOT immerse the unit in water or any other liquid

• To reduce the risk of fire or electric shock, DO NOT open service panels. There are no user

serviceable parts inside.

• Keep hands and other items away from hot areas of the unit during operation.

• Never clean with scouring powders or harsh chemicals.

CAUTION: DO NOT

connect the unit to

hot water supply.

The inlet valve is not rated for

hot water.

CAUTION: Follow

this setup procedure

before attempting

to use this unit. Failure to

follow these instructions can

result in injury and/or void of
warranty.

ISO 9001:2008 REGISTERED

WILBUR CURTIS CO.

6913 Acco Street,

Montebello, CA 90640-5403

For the latest information go to

www.wilburcurtis.com

Tel: 800/421-6150

Fax: 323/837-2410

CAUTION:

Equipment must be

installed to comply

with applicable federal, state,

and local plumbing/electrical

codes.

INSTALLATION

This Curtis unit is pre-set and ready to go from the factory.
System Requirements:

• Water Supply 20 – 90 PSI (MINIMUM FLOW RATE of 2 GPM)*
• Electrical: See electrical schematic.

3. Connect the unit to electrical outlet with appropriate amperage rating (See serial tag on ma-

chine).

4. Once power has been supplied to the unit, flip the toggle switch to the ‘ON’ position (located on

the rear of the unit), the water tank will begin to fill. When the water level in the tank reaches the

probe, the heating element will turn on.

5. During the initial setup, the heating tank will reach operating temperature in 60 to 70 minutes

(factory default 204°F).

* Expect flow rate from hot water faucet to be 1 GPM from WB5N and 2 GPM from WB5NL

NSF requires the following water connection:

1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so

that the unit can be moved for cleaning.

2. This unit must be installed with adequate backflow protection to comply with applicable federal,

state and local codes.

3. Water pipe connections and fixtures directly connected to a portable water supply shall be sized,

installed and maintained in accordance with federal, state, and local codes.

NOTE: A water filtration system must be used to help maintain trouble-free operation. Air must be

purged from the cartridge prior to connection to equipment. In areas with extremely hard wa-

ter, we highly recommend the use of a Curtis approved water filter. For our full line of filters, please

log on to www.wilburcurtis.com.

SETUP STEPS

1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet fitting on the rear of the unit. Water volume going to the

machine should be consistent. Use tubing sized sufficiently to provide a minimum flow rate of

two gallons per minute.

For the latest specifications and information go to www.wilburcurtis.com

Advertising
This manual is related to the following products: