TEMPERATURE SWITCHES

THERMOWELLS

Thermowells must be used on any
application where the bulb of the tem-
perature switch may be exposed to
pressure, corrosive fluids or high
velocity. Additionally, the use of a ther-
mowell permits instrument interchange
or calibration check without disturbing
or closing down the process.

Ashcroft temperature switches have
bulb diameters to match

3

8

˝ nominal

bore thermowells Is. The bulbs have a
sensitive portion length of 2˝ which can
be used with 2

1

2

˝ “U” dimensioned ther-

mowells or longer. For maximum accu-
racy a thermowells “U” dimension
should be selected to permit complete
immersion of the sensitive portion plus
1˝ when measuring the temperature of
liquids; an extra 3˝ should be allowed
when measuring the temperature
of gases.

Thermowell bushings should be used
with remote mount temperature switches.
We recommend the standard 3˝ bulb
and code 69 Series bushings for use
with any thermowell “U” dimension. A
split rubber grommet allows easy instal-
lation and “S” dimension adjustment.

To order a thermowell, refer to Price
Sheet TH/PS-1 for complete information.

B-Series temperature switches feature
a SAMA Class II vapor pressure ther-
mal system. This system provides
quick, accurate response to process
temperature changes with negligible
ambient temperature effects. This is
inherent in the design due to the pre-
cise relationship that exists between

temperature and pressure according to
the vapor pressure laws. A wide selec-
tion of sensing bulb and armored capil-
lary lengths is available. The vapor
pressure system design features small
bulb sizes, making installation easy and
cost-effective.

All models feature ±1.0% percent of

span setpoint repeatability with very
high overtemperature ratings.

These standard designs perform well in
applications where shock and vibration
could be a problem and should be used
with Ashcroft thermowells for bulb pro-
tection and ease of installation and
maintenance.

STANDARD TEMPERATURE RANGE SELECTION

NOTES:

1 All deadbands given in °F.
2 Available with remote mount thermal

systems only.

3 Not available with 2

3

4

˝ stem.

4 Dual switch element multiply single switch

element value by 1.6 for approximate
deadband.

5 Set and reset points must fall within the

adjustable range.

INSTRUMENT (SWITCH)

CONNECTION

Maximum

Nominal Range

(1)

Temperature

Approximate Deadband

(1)

Switch Element

°F

°C

°F

20, 26, 27

21, 24, 31

50

22

32

–40 to 60

–40 to 16

0

400

1.0-2.0

3.0-8.0

1.5-5.5

1.4-6.0

8.0-16.0

0 to 100

–20 to 40

0

400

1.5-3.0

5.0-12.0

2.2-8.5

1.5-7.5

9.0-20.0

75 to 205

20 to 95

400

1.5-3.5

8.0-16.0

2.5-12.0

2.0-9.0

10.0-24.0

150 to 260

65 to 125

400

1.5-3.0

5.0-12.0

2.2-8.5

2.0-9.0

10.0-24.0

235 to 375

110 to 190

500

1.5-3.5

5.0-12.0

2.5-8.5

2.0-9.0

10.0-24.0

350 to 525

(3)

175 to 275

700

2.0-4.5

8.0-16.0

3.2-12.0

2.5-10.0

15.0-34.0

500 to 750

(2)

260 to 400

900

4.0-8.0

16.0-30.0

7.2-24.0

5.0-23.0

30.0-50.0

Bushing slides
along capillary

69 series
(XBX) bushing

Process
connection

1/2" NPT

“S”

“S”