Model K1 Pressure Transducer/Transmitter

PHYSICAL SPECIFICATIONS

Enclosure: NEMA 4X (NEMA 1 only if <500 psig if
electrical termination is Bendix

®

or Hirschmann

®

)

Weight: 2 oz. (approx. w/o cable)

Reverse Polarity Protected

MATERIALS:

Case: 300 series stainless steel

Cable: No. 24 AWG, 36? PVC, shielded, vented,UL
approved

Diaphragm: 17-4 PH stainless steel

Standard Process Connections:
(316 stainless steel)

1

8

NPT male or female

1

4

NPT male or female

1

4

SAE-J-514 (male)

1

4

AMINCO (female) required for pressures over

10,000 psi Other connections available

How To Order

3.0

5/8

HEX

6-PIN BENDIX

0.9 SQ.

-------------------

4-PIN BENDIX

0.8 SQ.

3.0

HAZARDOUS LOCATION
CERTIFICATIONS

Factory Mutual

approvals:*

Intrinsically Safe for use in: Class I, II, III, Div. 1,
Groups A, B, C,D, F, G when used with safety
barriers in accordance with Ashcroft drawing
71B212 Sht (1-3).
Nonincendive for: Class I, Div. 2, Groups A, B, C, D
Special Protection for: Class II, III, Div. 2, Group F, G
*Note: Available with 4-20mA output only

1000

750

500

250

0

0

36

20

10

1182

30

Load Limitations 4-20mA Output Only

(R

LOOP

)

636

24

Loop Supply Voltage (VDC)

V

min

= 10V+ (.022A x R

L

)

R

L

= R

S

+ R

W

R

L

= Loop Resistance (ohms)

R

S

= Sense Resistance (ohms)

R

W

= Wire Resistance (ohms)

DIMENSIONS ( inches)

K 1

#

X

Type Configuration

(K1)

Pressure Connection

(MO1)

1

8

NPT-M

(FO1)

1

8

NPT-F

(MO2)

1

4

NPT-M

(FO2)

1

4

NPT-F

(MEK)

7

16

-20 SAE

(FO9)

9

16

-18 Female

Electrical Termination

(F2) 36˝ Cable, Shielded, PVC Sheathing

(B4) Bendix 4-pin #PTO2A-8-4P*

(B8) WP Bendix 4-pin #PTO2H-8-4P*

(B6) Bendix 6-pin #PTO2A-10-6P*

(B9) WP Bendix 6-pin #PTO2H-10-6P*

(C1)

1

2

NPT-M Conduit and 36˝ cable

(HM) Hirschmann Miniature

Accuracy/TC

(3) 0.50% ±0.014%/°F

(5) 0.50% ±0.028%/°F

(7) 1.0%

±0.040%/°F

Output Signal

(42) 4-20mA

(15) 1-5 Vdc

(16) 1-6 Vdc

(11) 1-11 Vdc

Pressure Range

(Vac/0) Vac/0 through (20,000)

20,000 psi (see Standard Ranges)

Call for more options

X Variations

(XFM)

FM Approval Option

(4-20mA output)

*Mating connector available as necessary

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: [email protected] • www.ashcroft.com

All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
© Ashcroft Inc. 2009 11/10

BULLETIN PT-1

Ash Bul PT-1:Layout

11/12/10

1:59 PM

Page 2

Advertising