Hazards identification, Composition/information on ingredients, First aid measures – Chemtronics Electro-Wash Two Step ES125A User Manual

Page 2

Advertising
background image

Electro-Wash Two-Step

2. Hazards identification

See toxicological information (Section 11)

Medical conditions
aggravated by over-
exposure

Pre-existing disorders involving any target organs mentioned in this MSDS as being at
risk may be aggravated by over-exposure to this product.

:

Over-exposure signs/symptoms

Ingestion

:

No specific data.

Skin

:

Adverse symptoms may include the following:
irritation
redness

Eyes

:

Adverse symptoms may include the following:
irritation
watering
redness

Inhalation

:

No specific data.

Target organs

:

Contains material which may cause damage to the following organs: upper respiratory
tract, central nervous system (CNS), eye, lens or cornea.

(2-methoxymethylethoxy)propanol

34590-94-8

20 - 40

N-methyl-2-pyrrolidone

872-50-4

20 - 30

3. Composition/information on ingredients

Name

CAS number

%

There are no additional ingredients present which, within the current knowledge of the supplier and in the
concentrations applicable, are classified as hazardous to health or the environment and hence require reporting
in this section.

Wash out mouth with water. Do not induce vomiting unless directed to do so by medical
personnel. Never give anything by mouth to an unconscious person. Get medical
attention immediately.

Check for and remove any contact lenses. Immediately flush eyes with plenty of water
for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical
attention immediately.
In case of contact, immediately flush skin with plenty of water for at least 15 minutes
while removing contaminated clothing and shoes. Wash clothing before reuse. Clean
shoes thoroughly before reuse. Get medical attention immediately.
Move exposed person to fresh air. If not breathing, if breathing is irregular or if
respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.
Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention
immediately.

4. First aid measures

Eye contact

Skin contact

Inhalation

Ingestion

In case of inhalation of decomposition products in a fire, symptoms may be delayed.
The exposed person may need to be kept under medical surveillance for 48 hours.

Notes to physician

:

:

:

:

:

Protection of first-aiders

:

No action shall be taken involving any personal risk or without suitable training. It may
be dangerous to the person providing aid to give mouth-to-mouth resuscitation.

2/10

ES125A

3/27/2013.

Advertising