M A T E R I A L S A F E T Y D A T A S H E E T

(MSDS)

118

ITEM NUMBER: 08658
VERSION 1 EFFECTIVE DATE: 11/18/03 SUPERCEDES: 00/00/00
PREPARED BY: Regulatory Compliance
Section(s) Revised: New product
IDENTITY (As Used On Label and List): FLORAL GARDEN ODOR COUNTERACTANT AIR NEUTRALIZER

Emergency Medical Telephone Number

1-800/836-8855 (24 HRS) Outside the U.S.A. Call 952-852-4646

*-*-*-*-*-*-*-*-*-*-*-*-*

SECTION I -*-*-*-*-*-*-*-*-*-*-*-


PRO-LINK

Canton, MA 02021

TELEPHONE NUMBER FOR INFORMATION: 1-800-74LINKS

DATE PRINTED: 3/1/05
NAME OF PREPARER: REGULATORY COMPLIANCE

*-*-*-*-*-*-* SECTION II - HAZARDOUS INGREDIENTS/IDENTITY INFORMATION -*-*-*-*-

EXPOSURE LIMITS
HAZARDOUS COMPONENTS OSHA PEL ACGIH OTHER % CAS NO
Acetone 750 ppm 750 ppm N/A 65-70 67-64-1
Diethylene Glycol Monoethyl Ether NE NE N/A 1-5 111-90-0
Pentane 600 ppm 600 ppm N/A 1-5 109-66-0
Propane 1000 ppm NE N/A 20-25 74-98-6

Abbreviations
NE: None established, N/A: Not applicable, *: ACGIH "STEL" Guidelines, ND: Not Determined, STEL: Short Term
Exposure Limits, !: Exxon/Mobil exposure limits for total Hydrocarbon

*-*-*-*-*-*-*-*- SECTION III - PHYSICAL CHARACTERISTICS -*-*-*-*-*-*-*-*-*-*-*-

BOILING POINT: ND VAPOR PRESSURE (mmHg or psig @ 70

°F): 70 +/- 5 psig

VAPOR DENSITY (AIR=1): Heavier than VAPOR PRESSURE (mmHg or psig @ 130

°F): 140 +/- 5 psig

SPECIFIC GRAVITY (H2O=1): 0.80-0.82 SOLUBILITY IN WATER % BY WT.: Negligible

VOC CONTENT % BY WT.: 29.49% EVAPORATION RATE (Butyl Acetate = 1): Faster than
APPERANCE AND ODOR: Clear liquid, with a country garden scent

*-*-*-*-*-*-*-*- SECTION IV - FIRE AND EXPLOSION HAZARD DATA -*-*-*-*-*-*-*-*-*-


FLASH POINT: Not Determined FLAMMABLE LIMITS: UEL 23.5 % LEL 1.2 %
EXTINGUISHING MEDIUM: AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
FIRE AND EXPLOSION HAZARD DATA
SPECIAL FIREFIGHTING PROCEDURES: Wear self-contained breathing apparatus when fighting fires containing or
around this product. Shut off all sources of ignition, if possible. Keep exposed containers cool with water spray to
prevent rupture. Evacuate all non-trained personnel. Wear full protective clothing, including helmet. Ventilate area.
Contain spill and dike, if possible. For leaks or spills water spray can be used to disperse any flammable vapors that
may become concentrated or form in poorly ventilated areas and to protect personnel attempting to stop the leak.
UNUSUAL FIRE AND EXPLOSION HAZARDS: Firefighters should wear SCBA's in a positive pressure mode with full
face shield. Vapors are heavier than air and may travel long distances and accumulate in low areas or spread along
ground from handling site. Eliminate all sources of ignition. Never use welding or cutting torch on or near this product
because even just residue can ignite explosively.

Page 1 of 3

Advertising