Recommended Calibration Procedure

The CP 52 is a very versatile instrument. While this allows it to conform to the requirements of a large number of system applica-

tions, it also results in complexity. For this reason, it is very important to use an organized approach to system calibration. Once the

system is connected and the internal switches set for your specific application, it is important to take the time for proper calibration.

The following is an ordered list of system adjustments that makes calibration easy and results in optimum performance.

This procedure assumes that a microphone is used for the Page. The procedure (except for the exact wording) is the same for other

Page sources.

Make sure the POWER is off!

PREFLIGHT CONTROL SETTINGS

PAGING SETTINGS:
• MIC/LINE Pad

As required

(front panel)

• INPUT TRIM

12:00 (center)

(front panel)

• DETECT THRESHOLD

Min (ccw, Active)

(front panel)

• Paging LEVEL

Min

(front panel)

• LIMIT THRESHOLD

+20 dBu

(front panel)

• MIC PHANTOM POWER

As required

(rear panel)

• LOW / HIGH CUT FILTER

As required

(rear panel)

• PAGE LEVEL TRACKS ZONE LEVEL OFF

(rear panel)

PROGRAM INPUT SETTINGS:
• Input Levels

Min

(front panel)

• PRIORITY DETECT THRESHOLD Set to -50 dBu at factory (range -∞ to -35 dBu; rear panel)

• PRIORITY RELEASE TIME

Set to 12 sec. at factory

(range 5 to 20 sec; rear panel)

• PRIORITY OFF / ON

OFF

(rear panel)

ZONE SETTINGS:
• DUCKER DEPTH

2:00 (about 15 dB)

(front panel)

• DUCKER OFF / ON

OFF

(front panel)

• PROGRAM SELECT

LINE 1, 2, 3 or P

(Any active Input; front panel)

• RMT (Remote)

Out (local control)

(front panel)

• Zone LEVEL

Max

(front panel)

• LIMIT THRESHOLD

+20 dBu

(front panel)

• Equalizer

Flat

(front panel)

• Zone Output MONO

As required

(rear panel)

• Expand ZONE/PROGRAM/PAGE

As required

(rear panel)

SYSTEM CONNECTIONS
• Connect page microphone or line level paging source

• Connect Program sources

• Connect Output to amps

• Connect ZR 1 Remote control (if required)

...You are now ready to calibrate the CP 52 (continued on next page...)