REMOTE MOUNTING

The ZR 1 and PR 2 remote assemblies mount in a standard

U.S. electrical box with a minimum depth of 2.25". Be sure to

note the wire color of each input in order to facilitate correct

wiring to the CP 64. Connect each wire to the 5-pin connec-

tor by fully inserting it in the correct socket and tightening the

screw. Make sure wires are free of nicks and that the cable jacket

is stripped back sufficiently to allow it to lie in the electrical box

with the remote assembly inserted. Use the flat head #6 screws

supplied with the kit to mount the remote assembly and silk-

screened front panel to the electrical box (see above diagram).

Note the “UP” arrow screened on the printed circuit board of

each remote (it should mount pointing up).

The silk-screened front panel metal is painted on both sides.

This allows you to custom silk-screen the panel or add your own

custom decals. Simply install the modified front panel with your

art facing out, and you are in business!

Install each knob so that the line on the knob is properly

aligned with the silk-screening on the front panel of the remote

assembly. Install any Decora plate of your choice. For a secured

installation, you may wish to leave the knobs off and use a blank

Decora plate to cover the remote after adjustment.

WIRE TYPES

Variations in wire type do not greatly affect the performance

of the remote controls. 22-gauge stranded wire with a flexible

jacket is recommended. You may use 5-conductor unshielded

remote control signal cable for shorter runs (less than 200 feet

[60 meters]), or 4-conductor (2 pair) shielded remote control

signal cable (use the shield as the ground return) for longer runs

(200 to 1000 feet [60 to 300 meters]). The type of wire required

is influenced by your installation and local electrical codes.

Rane Corporation does not provide or source cable. Please

contact your local retail or wholesale outlet, not the factory. The

following is a short list of suitable cable types:

CONSOLIDATED ELECTRONIC WIRE AND CABLE

Plenum cable:

Unshielded remote control signal cable CAT. # 9896

Shielded remote control signal cable CAT. #9877, CAT. #9852

WEICO WIRE & CABLE INC.

Communication and control cable:

Multiconductor, unshielded CAT. #7606

ALPHA

Communication and control cable:

Multiconductor, unshielded CAT. #1175C

BELDEN

Unshielded remote control signal cable CAT. # 88741

Shielded remote control signal cable CAT. # 88723

PAGE 2 ASSIGN

PAGE 1 ASSIGN

BOTH

OFF

BOTH

Z1

OFF

Z2

Z1 Z2

PROGRAM SELECT

LEVEL

8

2

10

0

4

6

L1

L3

L2

P

D

ec

or

a

pl

at

e

(n

ot

in

cl

ud

ed

)

D

ecora plate (not included

)

ZR 1

Zone / Volume

PR 2

Paging Assign / Volume

1

2

3

4

5

S2A

6

7

8

9

10

S2B

2

3

4

1

5

J1A

5 POS TERM

GND

GND

6

7

8

9

10

S1B

1

2

3

4

5

S1A

GND

GND

GND

Z2

Z1

GND

Z1

Z2

PAGE 1

PAGE 2

PAGE REMOTE (PR 2)

1

2

3

4

5

S1A

6

7

8

9

10

S1B

2

3

4

1

5

J1A

5 POS TERM

GND

GND

GND

D1

D0

Vc

Vr

ZONE REMOTE (ZR 1)

C

W

2

1

3

R1
2KRD

Advertising