Manual, Rear panel switch), Filters all bypass – Rane PEQ 55 User Manual

Page 5

Advertising
background image

Manual-

In and Out Level controls

LEVEL

controls serve three purposes, with the assistance of the In and Out Meters:

1. Adjust the IN signal level for good headroom and signal-to-noise.

2. Adjust the OUT signal level to compensate for changes in signal level due to filter boost/cut

settings.

3. Adjust sensitivity. The operation of the OUT LEVEL control is reversed from the IN LEVEL.

Pushing the control up reduces gain. Pushing the control down increases the gain. To easily

adjust sensitivity without affecting the output signal level, grasp the IN and OUT controls and

move them together. Only the A-channel IN and OUT LEVELs are active in 10-BAND mode.

In and Out Meters

IN

and OUT Meters are peak responding and indicate signal level in dBu.

Peak-dBu is held and displayed for 2 seconds. Attack is instantaneous. Decay is 500

ms for a 20 dB step. A and B meters remain active in linked 10-band mode.

EQ Bypass

BYPASS

switches have two modes of operation. If the rear

panel switch is set to BYPASS ALL, all filters and level controls

are bypassed. If this switch is set to BYPASS FILTERS, only

the filters are bypassed. Filters include Parametric, Tone and

Cut. An automatic relay bypass hardwires the Inputs to the

Outputs when the POWER is off.

A / B control switches

A / B

switches determine which set of controls is used by channel A and channel

B. There is a 100 ms mute to allow the filters to settle when the A/B control switch

is changed. The only control not affected by the A / B switches is BYPASS. A / B

control switches allow:

• Independent, dual mono operation

• A/B setting comparison

• 5-Band linked stereo operation (A or B controls affect both channels)

• Two “analog memories”

See the Applications section for example uses of the A / B switches.

10-Band mode / 5-Band mode

In 5-BAND mode, the PEQ 55 provides two independent 5-band parametric equalizers. A

or B controls may be used to control each channel as described above. In 10-BAND mode, both

channels are stereo linked and operation is as follows:

1. All 10 filters affect both A and B Outputs, permitting mono or stereo linked operation.

2. Meters remain independent and active for both channels.

3. Channel A and B BYPASS switches remain active.

4. A1 LOW SHELF and B5 HIGH SHELF modes are available.

(A5 high-shelf and B1 low-shelf filter modes are disabled.)

5. Channel A TONE, CUT FILTERS and LEVEL controls are active.

(Channel B tone, cut-filter and level controls are disabled.)

6. A / B control switches are inactive.

7. The Outputs mute for 200 ms when switched between 10-BAND and 5-BAND modes.

FILTERS

ALL

BYPASS

(rear panel switch)

PARAMETRIC

EQUALIZER

6

6

20k

7k

14k

5k

10k

15

120

30

240

60

6

6

20k

7k

14k

5k

10k

15

120

30

240

60

+6

-12 -6

-3

0

+3

+12 OL

12

12

12

12

12

12

12

12

+

+

0

+

0

+

0

0

+

+

0

+

0

+

0

0

+6

-12 -6

-3

0

+3

+12 OL

2

oct

dB

1

.5

1.5

Hz

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

2

1

.5

1.5

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

oct

dB

Hz

2

oct

dB

1

.5

1.5

Hz

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

2

1

.5

1.5

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

oct

dB

Hz

2

oct

dB

1

.5

1.5

Hz

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

2

1

.5

1.5

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

oct

dB

Hz

2

oct

dB

1

.5

1.5

Hz

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

2

1

.5

1.5

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

oct

dB

Hz

2

oct

dB

1

.5

1.5

Hz

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

2

1

.5

1.5

125

500

250

2k

1k

1

/

12

12

0

-6

6

-24

oct

dB

Hz

PEQ 55

BYPASS

GAIN

BW

LOW SHELF

x1
x10

x0.1

FREQUENCY

A1

LOW MID HIGH

LOW HIGH

IN

OUT

POWER

B

EQ

5-BAND

OUT

IN

10-BAND

BYPASS

A

CUT FILTERS

TONE

LEVEL

CUT FILTERS

TONE

LEVEL

A

B

EQ

OUT

IN

BYPASS

A

B

OL

OL

BYPASS

GAIN

BW

LOW SHELF

x1
x10

x0.1

FREQUENCY

B1

BYPASS

GAIN

BW

HIGH SHELF

x1
x10

x0.1

FREQUENCY

A5

OL

OL

BYPASS

GAIN

BW

HIGH SHELF

x1
x10

x0.1

FREQUENCY

B5

BYPASS

GAIN

BW

x1
x10

x0.1

FREQUENCY

A2

OL

OL

BYPASS

GAIN

BW

x1
x10

x0.1

FREQUENCY

B2

BYPASS

GAIN

BW

x1
x10

x0.1

FREQUENCY

A3

OL

OL

BYPASS

GAIN

BW

x1
x10

x0.1

FREQUENCY

B3

BYPASS

GAIN

BW

x1
x10

x0.1

FREQUENCY

A4

OL

OL

BYPASS

GAIN

BW

x1
x10

x0.1

FREQUENCY

B4

The active control surface for 0-BAND mode. Inactive controls are grayed out.

Advertising