Vp12man.pdf, Operators manual vp 12 – Rane VP 12 Manual User Manual

Page 3

Advertising
background image

Manual-

OPERATORS MANUAL

VP 12

VOICE PROCESSOR

WEAR PARTS:

This product contains no wear parts.

QUICK START

Even if you don’t like to read manuals, read this part. We’ll

make it quick and painless. We promise.

Turn down (fully counterclockwise) the MIC INPUT GAIN

and both MAIN and AUX OUTPUT LEVEL controls. Set

the LOW CUT FILTER to 10 (fully CCW) and the HI CUT

FILTER

to 40k (fully CW). Depress all BYPASS switches on

the front panel.

If you are using a mic, connect it to the MIC IN jack located

on the rear of the unit. If your mic requires phantom power,

press the rear panel 48V PHANTOM POWER switch. If you

are using a line level source (like the output of a wireless mic

receiver), connect its output to either the ¼" TRS jack or the

screw terminals located on the rear of the unit labeled LINE/

EXPAND IN

. Leave all jumpers located on the long screw ter-

minal patch strip in the original factory shipped position. These

positions guarantee you access to all the features of the VP 12.

Connect the Outputs of the VP 12 to your mixer board or

recorder. The switch located directly next to the XLR MAIN

OUT

jack converts the MAIN OUTs to either a MIC or LINE

level output, depending on your driving requirements. The AUX

OUT

of the VP 12 is only line level.

Plug the included power supply (see italics below) into the

VP 12. The yellow PWR LED will illuminate if all is well. Now

warn everyone else around, and yell into your mic the loudest

sound you expect during your session or performance. While

doing this adjust the INPUT GAIN control so that the loudest

sounds will occasionally illuminate the OL LED. If you are us-

ing the LINE IN, adjust the output level of the previous device

to occasionally illuminate the OL LED of the VP 12 when the

loudest signal you expect to hear is present.

Adjust the VP 12 OUTPUT LEVEL controls to match

the device you are driving. Now taking one processing section

at a time, release its BYPASS switch and adjust the processing

controls. Any number of processing sections may be IN or BY-

PASSED

to isolate different parameters. For details on setting

these properly see OPERATING INSTRUCTIONS on the last

two pages.

Never connect anything except an approved Rane power

supply to the thing that looks like a telephone jack on the rear
of the VP 12. This is an AC input and requires special atten-
tion if you do not have an operational power supply EXACT-
LY like the one originally packed with your unit.

Advertising