Hexin Technology HXSP-2108B Commercial Level RS-232 to RS-485/RS-422 Converter User Manual

Hexin Technology Hardware

Advertising
background image

Http://www.hexin-technology.com/

HXSP-2108B RS-232/RS-485/RS-422

Converter Instruction

Product introduction

HXSP-2108B is a multifunctional converter with external power supply, it

compatible with RS-232/RS-485/RS-422 standard. It can change the

single-ended RS-232 signal to balanced RS-485/RS-422 signal, RS-232

interface use the DB9 female connector connect with the serial of

computer ,on the other side RS -485/RS-422 use the DB9 male connect

with 6 terminal board, Or you can choose the RJ-45 port connect with the

device which has the RJ -45 connector . Since the RS-485 support two

wire half duplex, which means the RS-485 only have two lines to receive

data and send data. Handshaking signal usually control the direction of

data sending, the inner circuit of HXSP-2108B converter is able to auto

sensing the direction of data flow, and switch to ENABLE CONTROLS

automatic. A RS-485 network can be built convenient without any

handshaking signal; the RS-485 ENABLE CONTROLS is full transparent ,

no need to modify any software for the old working method based on

RS-232. HXSP-2108B converter comes with external power supply, the

characteristic have

small in

design, long

transmission distance,

performance stable, etc. it is mainly used for the field of electricity,

industrial automatic control, IC card billing system and time attendance,

one card solution, access control system, parking system, and so on.

Specification

1. Standard: Accord EIA RS-232, RS-485, RS-422 standard.

2. Connector: DB9 female on RS -232 side, DB9 male with 6 terminal block

on RS-485/RS-422 side or RJ-45 connector.

3. Work methods: asynchronous, point to point or multi -point, 2 wire

half-duplex.

4. Transmission medium: twisted pair cable or shielded Wire

5. Baud rate: 300~115000bps.

6. Signal indication: three signal indication LEDs(TXD,RXD,POWER).

7. Surge Protection: 1500W.

8. Transmission distance: 5 meters (RS-232 side) and 1800 meters

(RS-485/RS-422 side).

9. Dimension: 93mm x 23mm x 62mm.

10. Environment: -10℃ to 85℃ working temperature, 5% to 95% relative

humidity.

11. Loading Capacity: 32~128 units device.

Pin Definition:

RS-232 pin definition

D B 9 F e m a l e

1

2

3

4

5

6

7

8

RS-232

DCD

TXD

RXD

DTR

GND DSR RTS CTS

RS-485/RS-422 pin definition

D B 9 M a l e

1

2

3

4

5

6

RS-422

T-

T+

R+

R-

GND

FCN

RS-485

485-

485+

GND

FCN

RJ-45 pin definition

RJ-45

1

2

3

4

5

6

7

8

RS-422

T+

T-

R+

R-

GND

GND

RS-485

485-

485+

GND

GND

RJ-45 connection diagram

1

8

8

Male

1

F e ma l e

Application

Please read the instruction carefully before using HXSP-2108B converter, the

9pin female side of RS-232 cable comes with HXSP-2108B connect to the

RS-232 connector of Main Host Computer. And the other side connects to the

RS-232 connector of the HXSP-2108B. The power AC Adapte r connect to +9V

connector. Connect RS-45 or 6 terminal blocks on RS-485/RS-422 as

required, when connect all the terminal blocks, it must be according to the Pin

Definition.HXSP-2108B converters support 4 kinds of communication method

as below:

(1) Point to point /four wires full-duplex

(2) Point to points /four wires full-duplex

(3) Point to point /two wires half-duplex

(4) Point to points / two wires half-duplex

The factory settings is auto adaptation status, when the customer use external

connection as RS-485 , the HXSP-2108B will be in the half-duplex RS-485

status , and when the customer use external connection as RS-422 , the

HXSP-2108B will be in the full-duplex RS-422 status.

(1) When the HXSP-2108B connects as RS-232/RS-422, the device connects

as RS-422 connection method.

A. RS-232/RS-422 communicate as point to point four wire, asynchronous,

full-duplex method, this method is mainly used for control -side equipment

connector is RS-232, and the connector of equipment un der control is RS-422,

The two side can not communicate directly because of disaccord of two side

electrical specialty, HXSP-2108B converter can be used for transparent

change the RS-232 signals to RS-422 signals.

Advertising