CALIBRATION INSTRUCTIONS
To set the unit to match another hygrometer, you may adjust the
reading by up to 9% (+ or -) on your Cigar Oasis EXCEL.

1) Determine if you need to increase or decrease the reading on

the Cigar Oasis Humidifier to match the reading on your
separate digital hygrometer.

2) Press the UP and SUN button simultaneously and hold for 3

seconds to enter the Calibration Mode (Displays U 0).

3) Press UP button if you need to increase the reading on the

humidifier to match the reading on your separate hygrometer OR
Press the DOWN button if you need to decrease the reading on
the humidifier to match the reading on your separate
hygrometer.

4) Press SUN button to leave the Calibration Mode.
5) Allow the humidifier to run for at least an hour before you check

if humidity level matches the other hygrometer.

If further re-calibration is necessary, follow the above procedures
again. Re-calibration should not be done more than three times in a
row.