Cleveland Range 24-CGM-200 User Manual

Cleveland, Cleveland classic series, Cleveland standard features

Advertising
background image

Cleveland

Project ________________________________

Item __________________________________

Quantity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

1333 East 179 St.,

Cleveland, Ohio, U.S.A. 44110

Tel: 1-216-481-4900

Fax: 1-216-481-3782

Web Site: www.ClevelandRange.com

Email: [email protected]

CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE

SECT.

III

PAGE

3

0707

MODEL:

24-CGM-200

Cleveland Standard Features

Cooking Capacity for up to six 12˝ x 20˝ x 2

1

2

˝ deep Cafeteria Pans.

Pressureless cooking with forced convection steam, permitting
doors to be opened while cooking continues.

Solid State Controls operate water level and safety functions.

Each compartment is equipped with a 60 minute mechanical
timer, separate bypass switch for constant steaming and a
cold water condenser for superior cooking results.

Instant Steam Standby Mode: Holds generator at steaming
temperature. Allows unit to start cooking instantly.

Durable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.

Separate Main Power Switch for “On/Off”

Exclusive Steam Cooking Distribution System: The exclu-
sive Convection Jets produce a high velocity convection steam
without fans. Coved Corner design in cooking compartment distrib-
utes heat evenly and is easy to keep clean. Creased top & bottom
enhance drainage. Cold Water Condenser for each compartment
maintains a dry steam. Fully insulated cooking compartment for
thermal efficiency. Removable Stainless Steel Slide Racks for easy
cleaning.

Exclusive “Cool to the Touch” Compartment Door Design:
Free floating inner door with reversible door gasket provides
an air tight seal. Stainless Steel Slam/Latch Door Latch
mechanism provides greater reliability.

Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.

Modular Cabinet Base with Hinged Door.

High Efficiency Gas Steam Generator with NickelGuard,
Electronic Spark Ignition and Automatic Water Fill on start up.

Automatic Generator Drain at shutdown: Contains a “Water
Jet” Spray Rinse Cleaning Cycle to keep drain clear.

Automatic Generator Mineral Purging Cycle automatically
cleans generator, reducing scale build up

Automatic Water Level Control System with Low Water
Power Cut-off Circuit.

Steam generator equipped with High Limit Pressure Safety Switch,
15 psi Safety Valve, and Steam Generator Pressure Gauge.

NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.

Gas Pressure Regulator and Control Valve.

Standard Voltage for Control: 115 volts, 60 Hz, single phase.

All Controls are serviceable from the front.

Options & Accessories

❐ Right Hand Door Hinging, Controls on the Left (DHR)

❐ Electronic Timer with Compensating Load Feature (ETC)

❐ ON/OFF Steam Switch only for compartment controls (MC)

❐ Cafeteria pans in depths of 1˝, 2

1

2

˝, 4˝ and 6˝

❐ Power Take Off Kit (GPTO), Kettle Interconnecting Kit (IMK-)

❐ Correctional Packages

❐ Stainless Steel Base Frame (FSS)

❐ Stainless Steel Insulated Flue Cover (SSF)

❐ Quick Disconnect for gas line (QDC)

❐ Secondary Low Water Cut-Off, factory installed (CALG)

(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT.
NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)

❐ Compartment Door Steam Shut Off Switch (SCS)

❐ Boiler Descaling Pump Kit (107142)

❐ Water Filters

❐ Rear Gas Connection (RGT)

Shall be Two Compartments, CLEVELAND Convection Steamer, Model 24-

CGM-200, Gas-fired Steam Generator, NickelGuard, 200M BTU. Solid

State Controls operate timing, water level and safety functions. Steam

Generator with Automatic Water Fill on start-up, Automatic Blowdown with

additional Manual Drain Valve and Electronic Spark Ignition. For each

cooking compartment: 60 minute Mechanical Timer, Manual Operation

Mode and Cold Water Condenser. Type 304 Stainless Steel cooking com-

partment.

Short Form Specifications

Cleveland Classic Series

TWO COMPARTMENT, PRESSURELESS
200M BTU GAS FIRED STEAM GENERATOR
24” WIDE CABINET BASE DESIGN, with NICKELGUARD™

CONVECTION
STEAMERS

1

0

0

%

5

Ye

ar Boiler

W

a

rr

a

n

ty

N

ic

ke

lGuar

d

Advertising