9)

Place the two batteries on the shelf inside the enclosure, below the power source. Connect

the cable from the “BAT” terminal point on the power source to the two batteries (Red cable –
positive to the positive of one battery and Black cable

– negative to the negative of the other

battery. The two batteries are connected in series via two quick disconnect terminals on either
end of the cable).


10)

Place cover over enclosure and re-secure with screws removed in step 1.

III.

Programming

1)

Program EC-8 per Instructions packed with that unit. Be sure the EC-

8 is set for “LOCAL

PHONE ONLY” operation or “LOCAL/TELCO” alternation if an outside phone line or a PBX
line is used in the system.


2)

Program each Emergency Phone per Instructions packed with that phone. Be sure to
program feature *78* in addition to any other features selected. NOTE: If no outside phone
line or PBX line is used, program the number to be called as *13*5551234*. This is
necessary for proper system function.


Strobe/Siren Assembly