ETP-EL12/24 Installation Instructions


Copyright 2010 Talk-A-Phone Co. All rights reserved.

Page 3 of 3

Talk-A-Phone Co. • 7530 North Natchez Avenue • Niles, Illinois 60714-3804

Phone 773.539.1100 • Fax 773.539.1241 • [email protected] • www.talkaphone.com

All prices and specifications are subject to change without notice.

Talk-A-Phone is a registered trademark of Talk-A-Phone Co.


When using the blue light strobe with ETP-400 Series Emergency Phones, connect the orange and black auxiliary
control cable pair of the blue light strobe to the orange and black wires of the Emergency Phone. Refer to the
Emergency Phone Manual for information regarding the programming of your phone.

When using the ETP-EL12/24 Series blue light strobe with VOIP-500 Series Emergency Phones, connect the
orange and black auxiliary control cable pair of the blue light strobe to positions 3 and 4 (Aux. Output 2) of the 6-
pin connector plug of the VOIP-500 Series Phone.

V.

Low Power Mode

The ETP-EL12/24 blue strobe light can operate in either of the
two modes as follows:

1. Normal power mode (default mode)
2. Low power mode (power conservation mode)

For Low Power Mode:

a. Disconnect

the

ETP-EL12/24 blue strobe light from the

power source.

b. Untwist the Fresnel dome from the base of the ETP-

EL12/24 blue strobe light.

c. As shown in Figure 3, use the jumper to shunt the center

and the left side header positions on the 3-position
connector.

d. Fasten the Fresnel dome to the base of the ETP-EL12/24

blue strobe light and connect to the respective power
source.


Figure 3: Low power mode jumper