Talkaphone ETP-MT Blue Light Emergency Phone Tower User Manual

Page 2

Advertising
background image

TOWER PARTS Kit for installation of ETP-MT, ETP-MT/R or WEBS-MT/R

Copyright 2009 Talk-A-Phone Co. All rights reserved.


Talk-A-Phone

Co.

• 7530 North Natchez Avenue • Niles, Illinois 60714-3804

Page 2 of 2

Phone 773.539.1100 • Fax 773.539.1241 • [email protected] • www.talkaphone.com

All prices and specifications are subject to change without notice.

Talk-A-Phone, Talk-A-Lert, Scream Alert and WEBS are registered trademarks of Talk-A-Phone Co.

4. Wire incoming power to the blue light/strobe and to the faceplate light. The LED board operates on

12VDC up to 120VAC and is not polarity sensitive. The 120V strobe operates only on 120VAC. The
low voltage strobe light, if used, operates on 12/24VDC or 24VAC (do not exceed 24VAC) and is not
polarity sensitive. See wiring diagram below.

5. Connect the black and orange wires of the Emergency Phone to the black and orange control wires of

the blue light/strobe. These are the AUX 2 output leads (see Emergency Phone manual for
programming). Attach the Emergency Phone to the tower with six (6) 10-24 oval head tamperproof
screws included with the phone. Connect the phone line coming into the tower to the male RJ11
connector coming from the Emergency Phone. An outdoor rated RJ11 female modular jack on the
end of the incoming phone line is strongly recommended.

6. Re-attach the cover plate over the access opening.

IV.

12VDC/24VDC/24VAC Strobe Wiring Diagram

Combined Power Consumption for blue light strobe and faceplate light
Input Voltage: 10-28VDC
Input Current: Light only:

170mA at 12VDC or 185mA at 24VDC

When Flashing: 1.55A at 12VDC or 875mA at 24VDC


It is the installer’s obligation to ensure compliance with all national, regional, and local regulations.

Advertising