IV. Wiring Installation

1. Make all connections to the DIN Rail Terminal Block as shown in Table 1. When using the ETP-

EL12/24 (12 VDC), connect it (power) to terminal no. 49 (12 VDC Power (-), Black) and 56 (12 VDC
Power (+), White) on DIN Rail Terminal Block. When using the ETP-EL (120VAC), connect it (power)
directly to main 120 VAC power source

2. Connect the Paging Amplifier to the WEBS Loudspeakers, DIN Rail Terminal Block and the WEBS-

VCU as shown in Figure 4. Connect the speaker audio cables to their corresponding paging amplifier
speaker output cables as follows:





PAGING

AMPLIFIER

Power

Connections

Power - [RED]

Power - [BLACK]

Trigger

– [ORANGE]

POWER CABLE

[RED or WHITE]

[BLACK]

TRIGGER CABLE

[BLACK]

[ORANGE]

[RED or WHITE]

[BLACK]

[BLACK]

[ORANGE]

55

50

37

36

}

To DIN Rail
Terminal Block

Audio

Output

Audio

Input

[PURPLE]

[GREEN]

[GREY]

[WHITE]

{

To Speaker
Cables

RCA Cable 1

RCA Cable 2
RCA Cable 3

RCA Cable 4

}

To Audio Output on
WEBS-VCU




Figure 4.
Paging Amplifier, WEBS Loudspeakers, WEBS-VCU and DIN Rail Terminal Block Connectivity Layout


Speaker No.

Amplifier Cable

Speaker #1

White and White/Black

Speaker #2

Grey and Grey/Black

Speaker #3

Green and Green/Black

Speaker #4

Purple and Purple/Black