12 Vdc ADC Burner Manual

Section: Prepare Before Installing

Owner’s Responsibility

Incorrect installation, adjustment, and

use of this burner could result in severe

personal injury, death, or substantial

property damage from fi re, carbon

monoxide poisoning, soot or explosion.

Contact a professional, qualifi ed service agency for the

installation, adjustment and service of your oil heating

system. This work requires technical training, trade

experience, licensing or certifi cation in some states and

the proper use of special combustion test instruments.

Please carefully read and comply with the following

instructions:

y

Never store or use gasoline or other fl ammable liquids
or vapors near this burner or appliance.

y

Never attempt to burn garbage or refuse in this
appliance.

y

Never attempt to light the burner/appliance by throwing
burning material into the appliance.

y

Never attempt to burn any fuel not specifi ed and
approved for use in this burner.

y

Never restrict the air inlet openings to the burner or
the combustion air ventilation openings in the room.

Impaired Burner Performance
and Fire Hazard.

Do NOT operate the burner beyond specifi cations

outlined in the table to the right.

y

For applications beyond these limits, consult Beckett
Technical Service at 1-800-645-2876.

y

NOTE: Some packaged appliances with burners
may be agency listed as a unit to operate beyond
these limits. Consult the appliance manufacturer’s
specifi cations and agency approvals for verifi cation.

Prepare Before Installing

Notice Special Requirements

If you discover damage to the burner
or controls during unpacking, notify

the carrier at once and fi le the appropriate claim.

When contacting Beckett for service
information — Please record the

burner serial number (and have available when calling or
writing). You will fi nd the serial number on the silver label
located on the left rear of the burner. See Figure 1.

Specifi cations

Capacity

‘F’ Head

Firing Rate: 0.75 - 2.50 GPH
Input: 105,000 - 350,000 Btu/h

Fuels

USA: No. 1 or No. 2 diesel fuel or kerosene;
No.1 or No. 2 heating oil (ASTM D396)

DO NOT USE GAS-

OLINE, CRANKCASE OIL, OR ANY
OIL CONTAINING GASOLINE.

Electrical

Power Supply: 13.5 Vdc

Operating Load
w/ igniter on: 15 Amps
w/ igniter off: 8 - 10 Amps

Motor: 13.5Vdc, 1/6 hp, 3450 RPM, 10
Amps (max.) NEMA “M” Flange, rotation
CCW when facing shaft end.

Ignition Secondary: 20KVpk 25mA
Interrupted duty OR optional continuous
duty.

Pump

Outlet pressure: Note 1

Dimensions

Height (maximum): 11 ½ inches
Width (maximum): 14 3/8 inches
Depth (chassis only): 6 9/16 inches
Air tube diameter: 4 inches

Ambient
Operating
Temperature

+32° F. (0° C.) Minimum
+115° F. (+46° C.) Maximum
(See Warning on Impaired Burner
Performance and Fire Hazard.)

Note 1. See equipment manufacturer’s burner specifi cations
for recommended outlet pressure. Pressure is 100 psig unless
otherwise noted.