Beckett 7600 Quick Start User Manual

Uick, Eference, Uide

Advertising
background image

PARTS & ACCESSORIES

Q

uick

R

efeRence

G

uide

The Beckett AquaSmart is an advanced boiler control designed for use on residential and light commercial
boiler systems. All models include the option of enabling Beckett HeatManager™ dynamic temperature reset
that, when selected, provides up to 20% fuel consumption savings. The control includes a backlit LCD digital
display with touch pad to easily program temperature limits, differentials, and other advanced options. The
AquaSmart also has memory storage of system history for help with diagnostics and troubleshooting.

Temperature Ranges and Differentials

High Limit Setting Range: 100 to 240°F (38 to 116°C)

High Limit Differential Range: 5 to 45°F (3 to 25°C)

Low Limit Setting Range: 100 to 220°F (38 to 104°C)

Low Limit Differential Range: 10 to 45°F (6 to 25°C)

Factory Range Stops available - consult factory

Environmental Ratings

Storage Temperature: -40 to +150°F (-40 to +65°C)

Operating Temperature: -4 to +150°F (-20 to +65°C)

Maximum Sensing Element Temperature: 250°F (121°C)

Relative Humidity: 5 to 85% RH, non-condensing and

non-crystallizing

Technical Specifications

Electrical Ratings

Input Voltage: 120 Vac - 50/60 Hz.

Input Current: 0.1 A + B1 + C1 + ZC

MAX Input Current: 20A (Reduce to 15A if optional

power switch is used)

24 Vac Thermostat Anticipator Current: 0.1 Amp.

Burner Current Rating (B1):

7600A (oil): 7.4 A at 120 Vac FLA; 44.4 A inrush LRA.

7600B (gas): 1.25 A at 24 Vac; 30 VA (total load).

Circulator Current Rating (C1): 7.4 A at 120 Vac FLA;

44.4 A inrush LRA.

Zone Control Current Rating (ZC): 7.4 A at 120 Vac

FLA; 44.4 A inrush LRA.

Do Not Use This Control in an Application that is Not Within the Ratings

Listed in This Section. Improper Control Operation May Result.

Electrical Shock, Fire, Explosion and Burn Hazards

This control must be installed, adjusted and put into operation only by a trained, licensed, qualified

professional or service agency in accordance with the National Electric Code ANSI/NFPA 70 (Canada CSA

C22.1) state, local codes and authorities having jurisdiction.

The installer must carefully read and follow the installation and service instructions contained in this pamphlet and in

the owner’s manual. Make them available to the equipment owner, so they can be kept for future reference.

Please refer to the AquaSmart Owner’s Manual for more detailed instructions and advanced

programming options.

Approvals

Underwriters Laboratories Recognition to UL353, UL1998 for U.S. and Canada