Appendix, General troubleshooting, Eneral – Chauvet Home Safety Product User Manual

Page 11: Roubleshooting, Ppendix

Advertising
background image


5. Appendix

11

1/12/2011 11:51 AM

5.

A

PPENDIX

General Troubleshooting

S

YMPTOM

P

OSSIBLE

C

AUSE

(

S

)

P

OSSIBLE

A

CTION

(

S

)

Breaker/Fuse

keeps blowing

· Excessive circuit load

· Check total load placed on the electrical

circuit

· Short circuit along the power

wires

· Check for a short in the electrical wiring

(internal and/or external)

Device does not

power up

· No power

· Check for power on Mains

· Loose power cord

· Check power cord

Fixture is not

responding to DMX

· Wrong DMX addressing

· Check Control Panel and unit

addressing

· Damaged DMX cables

· Check DMX cables

· Wrong polarity settings on the

controller

· Check polarity switch settings on the

controller

· Loose DMX cables

· Check cable connections

· Faulty DMX interface

· Replace DMX input

· Faulty Main PCB

· Replace Main PCB

Loss of signal

· Non DMX cables

· Use only DMX compatible cables

· Bouncing signals

· Install terminator as suggested

· Long cable / low level signal

· Install amplifier right after fixture with

strong signal.

· Too many fixtures

· Install an optically coupled DMX splitter

after unit #32

· Interference from AC wires

· Keep DMX cables separated from power

cables or black lights

If you still have a problem after trying the above solutions, please contact CHAUVET® Technical
Support.

Advertising