The DELFX-UI shown in Figure B-2 uses an SC style connector that
supports multimode fiber optic cabling. Specifications for the DELFX-UI
are listed in Table B-1, below.

Figure B-2

DELFX-UI

Table B-1

Transmitter Power

Cable Type

Worst Case Budget

Typical Budget

50/125 µm fiber optic

6.0 dB

9.0 dB

62.5/125 µm fiber optic

9.0 dB

12.0 dB

100/140 µm fiber optic

15.0 dB

18.0 dB

The transmitter power levels and receive sensitivity levels
listed are peak power levels after optical overshoot. A peak
power meter must be used to correctly compare the values
given above to those measured on any particular port. If power
levels are being measured with an average power meter, add
3 dB to the measurement to compare the measured values to
the values listed above.