Charging Batteries

1. Insert 1 to 4 AA, AAA, C, D size or 1 to 2 9V rechargeable NiMH batteries into the battery

compartment, oriented according to the marked polarity (+ and –) symbols.

2. Multiple sizes of batteries can be inserted at one time. The charger will adjust charging

current for the different sizes automatically.

3. Connect the supplied power adapter into the DC Power Input Jack on the back and plug

it into your household electrical outlet.

4. The LCD Display will indicate the charging status and the word “CHARGE” will be shown

(see LCD Display Identification on page 2). The blue backlight will light up during the

charging process and turn off when charging has been completed.
Note:

9V batteries will charge for 10 hours and shut off, no matter what the charge level

is. Make sure 9V batteries are fully drained before charging them again. The discharge

function of the CC QuickCharger-2 will not discharge 9V batteries.

5. When the batteries are fully charged, the word “FULL” will be displayed.

6. Unplug the charger and remove the batteries. Do not leave batteries in the charger after

charging cycle is complete.

Discharging Batteries

1. Insert 1 to 4 AA, AAA, C, or D size rechargeable NiMH batteries into the battery compart-

ment, oriented according to the marked polarity (+ and –) symbols.

2. Connect the supplied power adapter into the DC Power Input Jack on the back and plug

it into your household electrical outlet.

3. Press the “Discharge Button” located on the left side of the LCD Display. The LCD Dis-

play will indicate the discharging status and the word “DISCHARGE” will be shown. The

blue backlight will light up during the discharging process.
Note:

The discharging process will not function if the “Discharge Button” is not pushed

within the first minute of the charging cycle.

5. The battery icons will continuously flash until all of the batteries have been discharged.

6. After the batteries are fully discharged, the charging process will begin automatically and

the word “CHARGE” will be shown in the display to indicate the charging cycle status.

USB Charge Function

1. The USB Port can be used after a battery charging cycle is complete or there are no bat-

teries in the charger compartment. The “USB Function Indicator” will be shown on the

display to indicate the USB Port is ready for use.

2. Any USB device with a maximum load not exceeding 500mA can be charged. Plug a

USB cable into the USB Port and connect your desired device. (USB cable not included.)

Bad Battery Detection

When the charge process has begun, the charger detects the status of each battery. If any

of the batteries are unsuitable for charging or inserted into the battery compartment incor-

rectly, the word “BAD” will be displayed and the battery icon will flash. Remove the bad bat-

tery or reinsert the battery correctly, if polarity is switched.